Civil Plan Set 10.19.202614
4
6 8
3
5 11
9
FULL DEPTH SAWCUT
FULL DEPTH SAWCUT
REMOVE SIGN
REMOVE SIGN
TREE PROTECTION FENCE
TREE PROTECTION FENCE
REMOVE LIGHT POLE
REMOVE LIGHT POLE
REMOVE LIGHT POLE
REMOVE CATCH BASIN
SEE C4-1 UTILITY PLAN
FOR NEW CONNECTION
PAST SOIL CONTAMINATION PRESENT
FOLLOW ALL RECOMMENDED SOIL TESTING
& DISPOSAL STEPS AS REQUIRED
COORDINATE WITH UTILITY PROVIDERS ON
SERVICES TO REMOVE OR REMAIN
PROTECT WALL
MAINTAIN PIPE
TO HYDRANT
SAWCUT & REMOVE
ENCLOSURE PAD
REMOVE GATE
REMOVE WALL &
FENCE FOR NEW GATE
& SIDEWALK CONNECTION
REMOVE
ENCLOSURE FENCE
LOUCKS
W:\2026\260351\CADD DATA\CIVIL\_dwg Sheet Files\C1-1 SITE DEMOLITION PLAN12755 Highway 55, Suite R100
Plymouth, MN 55441
763.424.5505
www.loucksinc.com
PLANNING
CIVIL ENGINEERING
LAND SURVEYING
LANDSCAPE ARCHITECTURE
ENVIRONMENTAL
C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e
instruments of the Consultant professional services for use solely
with respect to this project. These CADD files shall not be used
on other projects, for additions to this project, or for completion
of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he
C onsultant . With t he Cons ultant's appr oval, ot hers may be
per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or
information and reference only. All intentional or unintentional
revisions, additions, or deletions to these CADD files shall be
made at the full risk of that party making such revisions, additions
or deletions and that party shall hold harmless and indemnify the
Consultant from any & all responsibilities, claims, and liabilities.
CADD QUALIFICATION
QUALITY CONTROL
PROFESSIONAL SIGNATURE
SUBMITTAL/REVISIONS
BLAZE
CREDIT UNION
CHANHASSEN
320 Lake Drive East
Chanhassen, MN 55317
2025 Larpenteur Ave. W.
Falcoln Heights, MN 55113
C1-1 DEMOLITION PLAN
C2-1 SITE PLAN
C3-1 GRADING PLAN
C3-2 SWPPP
C3-2 SWPPP NOTES
C4-1 SANITARY AND WATERMAIN PLAN
C4-2 STORM SEWER PLAN
C8-1 CIVIL DETAILS
C8-2 CIVIL DETAILS
L0-1 TREE REPLACEMENT PLAN
L1-1 LANDSCAPE PLAN
L2-1 LANDSCAPE DETAILS
10/02/26 ENTITLEMENTS SUBMITTAL
License No.
Date
I hereby certify that this plan, specification or report was
prepared by me or under my direct supervision and that
I am a duly Licensed Professional Engineer under the
laws of the State of Minnesota.
46607
10/02/26
Brian M. Johnson - PE
Review Date
Project Lead
Drawn By
Checked By
Loucks Project No.
10/02/26
BMJ
BMJ
BMJ
260351
N
SCALE IN FEET
0 20 40
SITE
DEMOLITION
PLAN
C1-1
1.CONTRACTOR SHALL REMOVE AND/OR RELOCATE EXISTING PRIVATE UTILITIES AS NECESSARY.
CONTRACTOR TO COORDINATE ACTIVITIES WITH UTILITY COMPANIES & OWNER.
2.CLEAR AND GRUB AND REMOVE ALL TREES NOTED FOR REMOVAL, VEGETATION AND SITE DEBRIS
WITHIN CONSTRUCTION LIMITS PRIOR TO GRADING. STRIP TOP SOIL AND STOCKPILE ON-SITE. ALL
REMOVED MATERIAL SHALL BE HAULED FROM THE SITE DAILY. ALL CLEARING AND GRUBBING
AND REMOVALS SHALL BE PERFORMED PER THE CONTRACT SPECIFICATIONS. EROSION CONTROL
MEASURES SHALL BE IMMEDIATELY ESTABLISHED UPON REMOVAL. SEE THE STORMWATER
POLLUTION PREVENTION PLAN (SWPPP) / GRADING & EROSION CONTROL PLAN.
3.CONTRACTOR SHALL PROTECT SURFACE AND SUBSURFACE FEATURES NOT NOTED FOR REMOVAL.
CONTRACTOR TO NOTIFY ENGINEER WITH ANY CONFLICTS OR PLAN DISCREPANCIES.
4.CONTRACTOR TO SCHEDULE PRE-CONSTRUCTION MEETING(S) WITH UTILITY OWNER(S) TO
DISCUSS DISCONNECTIONS AND/OR RELOCATIONS.
5.REFER TO TREE INVENTORY, TREE PRESERVATION, AND TREE REPLACEMENT PLAN FOR REMOVAL
AND REPLACEMENT OF ON SITE TREES.
6.CONTRACTOR TO VERIFY LOCATION OF SEPTIC FIELD(S) & WELL(S) ON SITE. COORDINATE
REMOVALS AND/OR ABANDONMENT WITH THE APPLICABLE GOVERNING AGENCIES.
CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING APPLICABLE PERMITS. WELLS ON THE
PROPERTY SHALL BE SEALED BY A MINNESOTA DEPARTMENT OF HEALTH (MDH) LICENSED
CONTRACTOR.
7.BITUMINOUS PAVEMENT REMOVALS ARE TO BE MADE TO A VERTICAL SAW CUT OR TO A NEAT
MILLED EDGE.
8.CONCRETE PAVEMENT, SIDEWALK, CURB & GUTTER AND OTHER POURED CONCRETE ITEMS ARE TO
BE REMOVED TO AN EXISTING EXPANSION OR CONTRACTION JOINT. SAW CUT AS NECESSARY FOR
A NEAT EDGE OF REMOVAL.
9.ANY DAMAGE TO ITEMS NOT NOTED TO BE REMOVED SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR AND SHALL BE REPAIRED OR REPLACED TO ORIGINAL CONDITION WITH NO
ADDITIONAL COMPENSATION.
10.CONTRACTOR SHALL COORDINATE ALL WORK WITHIN THE PUBLIC RIGHT OF WAY WITH THE
APPLICABLE GOVERNING AGENCIES. ALL WORK SHALL BE PERFORMED PER THE REQUIREMENTS OF
THE APPLICABLE GOVERNING AGENCIES.
11.CONTRACTOR TO COORDINATE ALL WORK WITHIN THE ADJACENT PROPERTIES WITH THE OWNER
AND ADJACENT PROPERTY OWNER.
12.CONTRACTOR TO COORDINATE DEMOLITION PHASING WITH ALL DISCIPLINES INCLUDING BUT
NOT LIMITED TO ARCHITECTURAL, STRUCTURAL, ELECTRICAL, MECHANICAL, & OWNER.
13.REFER TO THE GEOTECHNICAL REPORT PREPARED BY XXX, DATED XX, XXXX FOR INFORMATION
INCLUDING BUT NOT LIMITED TO GROUNDWATER CONDITIONS AND RECOMMENDATIONS FOR
EXCAVATION DEWATERING.
14.THE CONTRACTOR SHALL COORDINATE WITH THE OWNER FOR ANY REPAIRS TO THE IRRIGATION
SYSTEM THAT IS AFFECTED DURING CONSTRUCTION.
SITE DEMOLITION NOTES
TOLL FREE: 1-800-252-1166
TWIN CITY AREA: 651-454-0002
Gopher State One Call
CALL BEFORE YOU DIG!
WARNING:
THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL
EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN
MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES.
THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT
LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES,
CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE
DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED
DURING CONSTRUCTION AT NO COST TO THE OWNER.
MILL AND OVERLAY EXISTING PARKING LOT
REMOVE EXISTING CURB & GUTTER, RETAINING WALLS,
FENCE, ETC.
REMOVE EXISTING MANHOLES, POWER POLES, LIGHT
POLES, BOLLARDS, PARKING METERS, SIGNS, ETC.
REMOVE EXISTING CONCRETE PAVING, SIDEWALKS,
ETC.
REMOVE EXISTING TREES
REMOVE EXISTING UTILITIES
REMOVE EXISTING BITUMINOUS PAVING
REMOVE EXISTING BUILDING
REMOVE EXISTING TREES/WOODS
REMOVE EXISTING GRAVEL
TREE PROTECTION FENCE
DEMOLITION LEGEND
FULL DEPTH SAW CUT
PSBLPSBLPSBLPSBLPSBLPSBLPSBLPSBL PSBL PSBL PSBL PSBL PSBL PSBL PSBL PSBL
PSBL
PSBL
PSBL
BSBL BSBL BSBL BSBL BSBL BSBL BSBL BSBL
BSBL
BSBL
BSBL BSBLBSBLBSBLBSBLBSBLBSBLBSBLBSBLBSBLBSBLBSBLBSBLBSBLBSBLBSBLBSBLBSBLBSBLBSBLBSBLBSBLBSBLNO PARKING
PROPOSED
CREDIT UNION
5,050 SF
FFE-949.25DO NOT ENTERxxxxFFE=949.25 BYPASS LANEB612 CURB/GUTTER-TYP
(SEE DETAIL)
20.0'
26.6'
18.0'
18.0'
18.5'
10.0'10.0'
18.5'
26.0'
9.0'
18.0'
9.0'
9.0'
26.0'
26.0'
18.0'18.0'
9.0'9.0'
6.0'
6.4'
6.0'
16.4'
30.4'
DOOR DOOR DRIVETHRUWINDOWSDOOR
10.3'
11.7'
10.3'
10.0'
10.0'PAVERS (SEE ARCH PLANS FOR
STYLE/PATTERN/DETAIL
HC SIGN (SEE DETAIL)
FLAT CURB (SEE DETAIL)
CURB TAPER
6.0'R3.0'
R14.0'
R3.0'
R3.0'
R3.0'
R3.0'
R28.5'
R14.0'
R16.0'
R15.0'R15.0'
6.0'
4.1'
MONUMENT SIGN
(BY OTHERS)
R3.0'
R3.0'
R5.0'
R3.0'R2.3'
R14.0'
R40.0'
R3.0'
R10.0'
R3.0'
R8.0'
R3.0'
CONCRETE
APRON
(SEE DETAIL)
CURB AND GUTTER
TO MATCH EXISTIN
IN R.O.W.
CURB AND GUTTER
TO MATCH EXISTIN
IN R.O.W.
2 FEET WIDE
BIT. PATCH
B612 CURB/GUTTER-TYP
(SEE DETAIL)
TRASH ENCLOSURE
(SEE ARCH PLANS)
SHARED WITH EAST
NEIGHBOR
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
CURB AND GUTTER
TO MATCH EXISTIN
IN R.O.W.
2 FEET WIDE
BIT. PATCH
CURB AND GUTTER
TO MATCH EXISTIN
IN R.O.W.
CURB TAPER
ADA RAMP
(SEE DETAIL)
ADA RAMP
(SEE DETAIL)
6 FOOT WIDE
CONCRETE
SIDEWALK
(SEE DETAIL)
B618 CURB/GUTTER
(SEE DETAIL)
B618 CURB/GUTTER
(SEE DETAIL)
9
8
11
7 8
MODIFIED CURB
(SEE ARCH DETAIL)
CURB TRANSITION
CURB TRANSITION
DO NOT ENTER SIGNS
DO NOT ENTER SIGNS
RETAINING WALL
NEW FENCE
TO REPLACE GATE
(MATCH EXISTING)
TRANSFORMER
(SEE ELEC)
FENCE (SEE ARCH)
CONDENSORS
5.0'
FENCE GATE
(MATCH EXISTING)
5.0'
PEDESTRIAN CROSS BARS
(SEE DETAIL)
REFER TO ARCH
PLANS FOR DRIVE
THROUGH
EQUIPMENT
INFORMATION
FOUR (4) PARKING
STALLS DESIGNATED FOR
EAST NEIGHBOR
CURB TAPER
LOUCKS
W:\2026\260351\CADD DATA\CIVIL\_dwg Sheet Files\C2-1 SITE PLAN12755 Highway 55, Suite R100
Plymouth, MN 55441
763.424.5505
www.loucksinc.com
PLANNING
CIVIL ENGINEERING
LAND SURVEYING
LANDSCAPE ARCHITECTURE
ENVIRONMENTAL
C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e
instruments of the Consultant professional services for use solely
with respect to this project. These CADD files shall not be used
on other projects, for additions to this project, or for completion
of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he
C onsultant . With t he Cons ultant's appr oval, ot hers may be
per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or
information and reference only. All intentional or unintentional
revisions, additions, or deletions to these CADD files shall be
made at the full risk of that party making such revisions, additions
or deletions and that party shall hold harmless and indemnify the
Consultant from any & all responsibilities, claims, and liabilities.
CADD QUALIFICATION
QUALITY CONTROL
PROFESSIONAL SIGNATURE
SUBMITTAL/REVISIONS
BLAZE
CREDIT UNION
CHANHASSEN
320 Lake Drive East
Chanhassen, MN 55317
2025 Larpenteur Ave. W.
Falcoln Heights, MN 55113
C1-1 DEMOLITION PLAN
C2-1 SITE PLAN
C3-1 GRADING PLAN
C3-2 SWPPP
C3-2 SWPPP NOTES
C4-1 SANITARY AND WATERMAIN PLAN
C4-2 STORM SEWER PLAN
C8-1 CIVIL DETAILS
C8-2 CIVIL DETAILS
L0-1 TREE REPLACEMENT PLAN
L1-1 LANDSCAPE PLAN
L2-1 LANDSCAPE DETAILS
10/02/26 ENTITLEMENTS SUBMITTAL
License No.
Date
I hereby certify that this plan, specification or report was
prepared by me or under my direct supervision and that
I am a duly Licensed Professional Engineer under the
laws of the State of Minnesota.
46607
10/02/26
Brian M. Johnson - PE
Review Date
Project Lead
Drawn By
Checked By
Loucks Project No.
10/02/26
BMJ
BMJ
BMJ
260351
N
SCALE IN FEET
0 20 40
SITE PLAN
C2-1
TOLL FREE: 1-800-252-1166
TWIN CITY AREA: 651-454-0002
Gopher State One Call
CALL BEFORE YOU DIG!
WARNING:
THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL
EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN
MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES.
THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT
LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES,
CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE
DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED
DURING CONSTRUCTION AT NO COST TO THE OWNER.
1.ALL PAVING, CONCRETE CURB, GUTTER AND SIDEWALK SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH THE
DETAILS SHOWN PER THE DETAIL SHEET(S) AND STATE/LOCAL JURISDICTION REQUIREMENTS.
2.ACCESSIBLE PARKING AND ACCESSIBLE ROUTES SHALL BE PROVIDED PER CURRENT ADA STANDARDS AND LOCAL/STATE
REQUIREMENTS.
3.ALL CURB DIMENSIONS SHOWN ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED.
4.ALL BUILDING DIMENSIONS ARE TO THE OUTSIDE FACE OF WALL UNLESS OTHERWISE NOTED.
5.TYPICAL FULL SIZED PARKING STALL IS 9' X 18' UNLESS OTHERWISE NOTED. DRIVE AISLES ARE 26' IN WIDTH.
6.SEE SITE ELECTRICAL PLAN FOR SITE LIGHTING.
CURRENT ZONING:BN NEIGHBORHOOD BUSINESS DISTRICT
PROPOSED ZONING:BN NEIGHBORHOOD BUSINESS DISTRICT
PROPERTY AREA:58,766 ± SF (1.35 ± AC)
EXISTING IMPERVIOUS AREA:44,647 SF (76.0%)
PROPOSED IMPERVIOUS AREA:38,014 SF (64.7%)
PROPOSED PARKING:43 STALLS PROVIDED
STANDARD STALLS:41
ADA ACCESSIBLE STALLS:2 (2 STALLS REQUIRED)
1.MINNESOTA STATE STATUTE REQUIRES NOTIFICATION PER "GOPHER STATE ONE CALL" PRIOR TO COMMENCING ANY GRADING,
EXCAVATION OR UNDERGROUND WORK.
2.THE CONTRACTOR SHALL FIELD VERIFY LOCATIONS AND ELEVATIONS OF EXISTING UTILITIES AND TOPOGRAPHIC FEATURES PRIOR TO
COMMENCEMENT OF CONSTRUCTION ACTIVITY. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES OR
VARIATIONS FROM THE PLANS.
3.THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO AVOID PROPERTY DAMAGE TO ADJACENT PROPERTIES DURING THE
CONSTRUCTION PHASE OF THIS PROJECT. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ANY DAMAGES TO ADJACENT PROPERTIES
OCCURRING DURING THE CONSTRUCTION PHASE OF THIS PROJECT.
4.THE CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING AND MAINTAINING TRAFFIC CONTROL DEVICES SUCH AS BARRICADES,
WARNING SIGNS, DIRECTIONAL SIGNS, FLAGMEN AND LIGHTS TO CONTROL THE MOVEMENT OF TRAFFIC WHERE NECESSARY.
PLACEMENT OF THESE DEVICES SHALL BE APPROVED BY THE ENGINEER PRIOR TO PLACEMENT. TRAFFIC CONTROL DEVICES SHALL
CONFORM TO THE APPROPRIATE MINNESOTA DEPARTMENT OF TRANSPORTATION STANDARDS.
5.IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY
RESPONSIBLE FOR CONDITIONS ON THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING THE PERFORMANCE OF
THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS.
6.ALL ENTRANCES AND CONNECTIONS TO CITY STREETS SHALL BE CONSTRUCTED PER THE REQUIREMENTS OF THE STATE AND LOCAL
JURISDICTIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITS AND NOTIFICATIONS AS REQUIRED.
CONCRETE PAVEMENT
LIGHT DUTY BITUMINOUS PAVEMENT
SITE NOTES
SITE DATA
GENERAL NOTES
PAVEMENT LEGEND
HEAVY DUTY CONCRETE PAVEMENT
PARKING STALL COUNT
ACCESSIBLE PARKING STALL
2
LEGEND
CATCH BASIN
STORM SEWER
SANITARY SEWER
WATERMAIN
STORM MANHOLE
SANITARY MANHOLE
HYDRANT
GATE VALVE
SPOT ELEVATION
SIGN
LIGHT POLE
POWER POLE
WATER MANHOLE / WELL
CONTOUR
CONCRETE CURB
UNDERGROUND ELECTRIC
CONCRETE
TELEPHONE PEDESTAL
UNDERGROUND TELEPHONE
UNDERGROUND GAS
OVERHEAD UTILITY
CHAIN LINK FENCE
BUILDING
RETAINING WALL
NO PARKING
UNDERGROUND FIBER OPTIC
SANITARY SEWER SERVICE
WATER SERVICE
ELECTRIC METER
GAS METER
TREE LINE
EXISTING PROPOSED
972
DRAINTILE
373PARKING SETBACK LINE
BUILDING SETBACK LINE
2
FENCE
FLARED END SECTION
POST INDICATOR VALVE
BENCHMARK
SOIL BORING
3DIRECTION OF FLOW 1.0%
972.5
HEAVY DUTY BITUMINOUS PAVEMENT
NO PARKING
PROPOSED
CREDIT UNION
5,050 SF
FFE-949.25DO NOT ENTER948.75
948.82
948.47
948.16
947.60
947.69
947.20
946.89
946.46
947.59
947.48947.82
947.04947.43
949.21
949.21
950.25
950.27
948.61
948.00
948.65
947.48
947.65
947.83
947.88
947.80
947.45
947.05
947.12
947.27
947.68
948.47
948.53
948.13
948.08948.11
948.16948.59
948.50948.34
947.86
948.01 948.31
948.45948.37
948.40
948.41
948.29
2
.
5%
3.2%
3.4%2.4%2.3%2.4%2.
5
%
2.1%
1.8%1.8%2.8%
1.8%1.6%5
.
6%4.0%4.3%7.2%3.2%7.1%8.0%FFE=949.25
947
948
949
948.86 948.86 948.461.8%1.8%2.0%1.9%948.12948.54
948.30
947.48
947.86
947.56
948.45
948.27
948.47
948.78
948.78 947.75
947.75
948.95
947.92
949.06
9
4
8948949
9489
4
8
948
948.50
950
949
950
951
952
950 949947948 9
50
947
9
4
8
9498888888
8
95095095094894995195210:15:16:14:14:124:1GW=950.04 GW=950.39
TW=950.41TW=952.28TW=952.52
TW=950.06
88888 8 88
8888888948.10
948.20
948.19 948.10
8
8
8
81.8%1.8%1.8%945.90 945.93
947.73947.75
948.26 948.22
947.73
947.75
947.76
947.72
EXISTING WALL
ON NEIGHBORING PROPERTY
PROTECT
LOUCKS
W:\2026\260351\CADD DATA\CIVIL\_dwg Sheet Files\C3-1 GRADING PLAN12755 Highway 55, Suite R100
Plymouth, MN 55441
763.424.5505
www.loucksinc.com
PLANNING
CIVIL ENGINEERING
LAND SURVEYING
LANDSCAPE ARCHITECTURE
ENVIRONMENTAL
C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e
instruments of the Consultant professional services for use solely
with respect to this project. These CADD files shall not be used
on other projects, for additions to this project, or for completion
of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he
C onsultant . With t he Cons ultant's appr oval, ot hers may be
per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or
information and reference only. All intentional or unintentional
revisions, additions, or deletions to these CADD files shall be
made at the full risk of that party making such revisions, additions
or deletions and that party shall hold harmless and indemnify the
Consultant from any & all responsibilities, claims, and liabilities.
CADD QUALIFICATION
QUALITY CONTROL
PROFESSIONAL SIGNATURE
SUBMITTAL/REVISIONS
BLAZE
CREDIT UNION
CHANHASSEN
320 Lake Drive East
Chanhassen, MN 55317
2025 Larpenteur Ave. W.
Falcoln Heights, MN 55113
C1-1 DEMOLITION PLAN
C2-1 SITE PLAN
C3-1 GRADING PLAN
C3-2 SWPPP
C3-2 SWPPP NOTES
C4-1 SANITARY AND WATERMAIN PLAN
C4-2 STORM SEWER PLAN
C8-1 CIVIL DETAILS
C8-2 CIVIL DETAILS
L0-1 TREE REPLACEMENT PLAN
L1-1 LANDSCAPE PLAN
L2-1 LANDSCAPE DETAILS
10/02/26 ENTITLEMENTS SUBMITTAL
License No.
Date
I hereby certify that this plan, specification or report was
prepared by me or under my direct supervision and that
I am a duly Licensed Professional Engineer under the
laws of the State of Minnesota.
46607
10/02/26
Brian M. Johnson - PE
Review Date
Project Lead
Drawn By
Checked By
Loucks Project No.
10/02/26
BMJ
BMJ
BMJ
260351
N
SCALE IN FEET
0 20 40
GRADING
PLAN
C3-1
TOLL FREE: 1-800-252-1166
TWIN CITY AREA: 651-454-0002
Gopher State One Call
CALL BEFORE YOU DIG!
WARNING:
THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL
EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN
MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES.
THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT
LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES,
CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE
DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED
DURING CONSTRUCTION AT NO COST TO THE OWNER.
1.SPOT ELEVATIONS REPRESENT FINISHED SURFACE GRADES, GUTTER/FLOW LINE, FACE OF BUILDING, OR EDGE OF
PAVEMENT UNLESS OTHERWISE NOTED.
2.CATCH BASINS AND MANHOLES IN PAVED AREAS SHALL BE SUMPED 0.04 FEET. ALL CATCH BASINS IN GUTTERS SHALL BE
SUMPED 0.10 FEET. RIM ELEVATIONS SHOWN ON PLANS DO NOT REFLECT SUMPED ELEVATIONS.
3.ALL DISTURBED UNPAVED AREAS ARE TO RECEIVE MINIMUM OF 4 INCHES OF PREMIUM TOP SOIL AND SEED/MULCH OR
SOD. THESE AREAS SHALL BE WATERED/MAINTAINED BY THE CONTRACTOR UNTIL VEGETATION IS ESTABLISHED. VERIFY
WITH LANDSCAPE PLAN.
4.REFER TO THE REPORT OF GEOTECHNICAL EXPLORATION BY BRAUN INTERTEC DATED ****pending**** AND REVIEW FOR
AN EXISTING SUBSURFACE SITE CONDITION ANALYSIS AND CONSTRUCTION RECOMMENDATIONS.
5.THE CONTRACTOR ALONG WITH THE OWNER SHALL OBTAIN ALL NECESSARY PERMITS AND APPROVALS FROM
GOVERNING AUTHORITIES, INCLUDING ANY CITY PERMITS AND THE NPDES PERMIT FROM THE MPCA.
6.INSTALL EROSION CONTROL AND TREE PROTECTION MEASURES BEFORE BEGINNING SITE GRADING ACTIVITIES. SOME
EROSION CONTROLS SUCH AS BALE CHECKS AND TEMPORARY SILT PONDS MAY BE INSTALLED AS GRADING OCCURS IN
SPECIFIC AREAS. MAINTAIN EROSION CONTROLS THROUGHOUT THE GRADING PROCESS AND REMOVE WHEN TURF HAS
BEEN ESTABLISHED.
7.THE CONTRACTOR SHALL ADHERE TO ALL REQUIREMENTS OF THE MPCA NPDES PERMIT. THE AREA TO BE DISTURBED
SHALL BE MINIMIZED AND TURF SHALL BE ESTABLISHED WITHIN THE TIME REQUIRED.
8.GRADES SHOWN ARE FINISHED GRADES.
9.FINAL GRADING TOLERANCES ARE +/-0.1 FEET TO FINISH GRADES.
10.UNDER PAVEMENTS COMPACT THE UPPER 3 FEET OF SUBGRADE TO 100% STANDARD PROCTOR DENSITY AT OPTIMUM
MOISTURE CONTENT AND 95% STANDARD PROCTOR DENSITY BLOW THE UPPER 3 FEET OF SUBGRADE. OUTSIDE
PAVEMENT AREAS COMPACT EMBANKMENTS TO 95% STANDARD PROCTOR DENSITY.
11.A CITY RIGHT-OF-WAY PERMIT MAY BE REQUIRED PRIOR TO WORKING WITHIN CITY ROW.
12.TURF REINFORCEMENT MAT (TRM) SHALL BE LANDLOK 450, AS MANUFACTURED BY PROPEX GEOSOLUTIONS, OR
APPROVED EQUAL. THE CONTRACTOR SHALL FOLLOW ALL OF THE MANUFACTURERS INSTRUCTIONS FOR
INSTALLATION.
13.WORKING HOURS ARE 7:00 AM - 7:00 PM, MONDAY - FRIDAY; 9:00 AM TO 5:00 PM SATURDAYS. A 48 HOUR NOTICED IS
REQUIRED FOR SATURDAY WORK.
14.DECOMPACTION OF ALL SOIL SURFACES COMPACTED DURING CONSTRUCTION AND REMAINING PERVIOUS UPON
COMPLETION OF CONSTRUCTION SHALL ACHIEVE A SOIL COMPACTION TESTING PRESSURE OF LESS THAN 1,400
KILOPASCALS OR 200 POUNDS PER SQUARE INCH IN THE UPPER 12 INCHES OF SOIL OR A BULK DENSITY OF LESS THAN
1.4 GRAMS PER CUBIC CENTIMETER OR 87 POUNDS PER CUBIC FOOT IN THE UPPER 12 INCHES OF SOIL.
15.CONSTRUCTION ACTIVITIES SHALL BE CONDUCTED SO AS TO MINIMIZE THE POTENTIAL TRANSFER OF AQUATIC
INVASIVE SPECIES (E.G., ZEBRA MUSSELS, EURASIAN WATERMILFOIL, ETC.) TO THE MAXIMUM EXTENT POSSIBLE.
GRADING & DRAINAGE NOTES
PARKING STALL COUNT
ACCESSIBLE PARKING STALL
2
LEGEND
CATCH BASIN
STORM SEWER
SANITARY SEWER
WATERMAIN
STORM MANHOLE
SANITARY MANHOLE
HYDRANT
GATE VALVE
SPOT ELEVATION
SIGN
LIGHT POLE
POWER POLE
WATER MANHOLE / WELL
CONTOUR
CONCRETE CURB
UNDERGROUND ELECTRIC
CONCRETE
TELEPHONE PEDESTAL
UNDERGROUND TELEPHONE
UNDERGROUND GAS
OVERHEAD UTILITY
CHAIN LINK FENCE
BUILDING
RETAINING WALL
NO PARKING
UNDERGROUND FIBER OPTIC
SANITARY SEWER SERVICE
WATER SERVICE
ELECTRIC METER
GAS METER
TREE LINE
EXISTING PROPOSED
972
DRAINTILE
373PARKING SETBACK LINE
BUILDING SETBACK LINE
2
FENCE
FLARED END SECTION
POST INDICATOR VALVE
BENCHMARK
SOIL BORING
3DIRECTION OF FLOW 1.0%
972.5
NO PARKING
PROPOSED
CREDIT UNION
5,050 SF
FFE-949.25DO NOT ENTERFFE=949.25
947
948
949
9
4
8948949
9489
4
8
948
950
949
950
951
952
950 949947948 9
50
947
9
4
8
9498888888
8
95095095094894995195288888 8 88
88888888
8
8
8SFSFSFSFSFSFSFSFSF
SF
SF
SF
SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFEROSION
CONTROL FABRIC
SILT FENCE-TYP
(SEE DETAIL)
SILT FENCE-TYP
(SEE DETAIL)
INLET
PROTECTION-TYP
(SEE DETAIL)INLET
PROTECTION-TYP
(SEE DETAIL)
ROCK CONSTRUCTION
ENTRANCE
LOUCKS
W:\2026\260351\CADD DATA\CIVIL\_dwg Sheet Files\C3-2 SWPPP PLAN12755 Highway 55, Suite R100
Plymouth, MN 55441
763.424.5505
www.loucksinc.com
PLANNING
CIVIL ENGINEERING
LAND SURVEYING
LANDSCAPE ARCHITECTURE
ENVIRONMENTAL
C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e
instruments of the Consultant professional services for use solely
with respect to this project. These CADD files shall not be used
on other projects, for additions to this project, or for completion
of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he
C onsultant . With t he Cons ultant's appr oval, ot hers may be
per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or
information and reference only. All intentional or unintentional
revisions, additions, or deletions to these CADD files shall be
made at the full risk of that party making such revisions, additions
or deletions and that party shall hold harmless and indemnify the
Consultant from any & all responsibilities, claims, and liabilities.
CADD QUALIFICATION
QUALITY CONTROL
PROFESSIONAL SIGNATURE
SUBMITTAL/REVISIONS
BLAZE
CREDIT UNION
CHANHASSEN
320 Lake Drive East
Chanhassen, MN 55317
2025 Larpenteur Ave. W.
Falcoln Heights, MN 55113
C1-1 DEMOLITION PLAN
C2-1 SITE PLAN
C3-1 GRADING PLAN
C3-2 SWPPP
C3-2 SWPPP NOTES
C4-1 SANITARY AND WATERMAIN PLAN
C4-2 STORM SEWER PLAN
C8-1 CIVIL DETAILS
C8-2 CIVIL DETAILS
L0-1 TREE REPLACEMENT PLAN
L1-1 LANDSCAPE PLAN
L2-1 LANDSCAPE DETAILS
10/02/26 ENTITLEMENTS SUBMITTAL
License No.
Date
I hereby certify that this plan, specification or report was
prepared by me or under my direct supervision and that
I am a duly Licensed Professional Engineer under the
laws of the State of Minnesota.
46607
10/02/26
Brian M. Johnson - PE
Review Date
Project Lead
Drawn By
Checked By
Loucks Project No.
10/02/26
BMJ
BMJ
BMJ
260351
N
SCALE IN FEET
0 20 40
SWPPP PLAN
C3-2
SEE SHEET C3-3 FOR SWPPP NOTES AND C8-1 FOR SWPPP DETAILS.
GENERAL NOTES
TOLL FREE: 1-800-252-1166
TWIN CITY AREA: 651-454-0002
Gopher State One Call
CALL BEFORE YOU DIG!
WARNING:
THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL
EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN
MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES.
THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT
LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES,
CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE
DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED
DURING CONSTRUCTION AT NO COST TO THE OWNER.
SWPPP LEGEND
INLET PROTECTION
SF SILT FENCE
BIO ROLLS
ROCK CONSTRUCTION
ENTRANCE
EROSION CONTROL
FABRIC
LOUCKS
W:\2026\260351\CADD DATA\CIVIL\_dwg Sheet Files\C3-3 SWPPP NOTES12755 Highway 55, Suite R100
Plymouth, MN 55441
763.424.5505
www.loucksinc.com
PLANNING
CIVIL ENGINEERING
LAND SURVEYING
LANDSCAPE ARCHITECTURE
ENVIRONMENTAL
C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e
instruments of the Consultant professional services for use solely
with respect to this project. These CADD files shall not be used
on other projects, for additions to this project, or for completion
of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he
C onsultant . With t he Cons ultant's appr oval, ot hers may be
per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or
information and reference only. All intentional or unintentional
revisions, additions, or deletions to these CADD files shall be
made at the full risk of that party making such revisions, additions
or deletions and that party shall hold harmless and indemnify the
Consultant from any & all responsibilities, claims, and liabilities.
CADD QUALIFICATION
QUALITY CONTROL
PROFESSIONAL SIGNATURE
SUBMITTAL/REVISIONS
BLAZE
CREDIT UNION
CHANHASSEN
320 Lake Drive East
Chanhassen, MN 55317
2025 Larpenteur Ave. W.
Falcoln Heights, MN 55113
C1-1 DEMOLITION PLAN
C2-1 SITE PLAN
C3-1 GRADING PLAN
C3-2 SWPPP
C3-2 SWPPP NOTES
C4-1 SANITARY AND WATERMAIN PLAN
C4-2 STORM SEWER PLAN
C8-1 CIVIL DETAILS
C8-2 CIVIL DETAILS
L0-1 TREE REPLACEMENT PLAN
L1-1 LANDSCAPE PLAN
L2-1 LANDSCAPE DETAILS
10/02/26 ENTITLEMENTS SUBMITTAL
License No.
Date
I hereby certify that this plan, specification or report was
prepared by me or under my direct supervision and that
I am a duly Licensed Professional Engineer under the
laws of the State of Minnesota.
46607
10/02/26
Brian M. Johnson - PE
Review Date
Project Lead
Drawn By
Checked By
Loucks Project No.
10/02/26
BMJ
BMJ
BMJ
260351
SWPPP NOTES
C3-3
1.THE NATURE OF THIS PROJECT WILL CONSIST OF CONSTRUCTING A SINGLE STORY
CREDIT UNION & THE ASSOCIATED PARKING, UTILITIES, & STORM WATER
MANAGEMENT AREAS .
2.THE INTENDED SEQUENCING OF MAJOR CONSTRUCTION ACTIVITIES ARE AS
FOLLOWS:
A.INSTALL VEHICLE TRACKING BMP
B.INSTALL SILT FENCE AND BIO-ROLLS AROUND SITE
C.CLEAR AND GRUB SITE
D.STRIP AND STOCKPILE TOPSOIL
E.REMOVE PAVEMENTS AND UTILITIES
F.CONSTRUCT STORMWATER MANAGEMENT BASINS
G.ROUGH GRADE SITE
H.IMPORT CLEAN FILL FOR REPLACEMENT AND BALANCE
I.INSTALL UTILITIES
J.INSTALL BUILDING FOUNDATIONS
K.INSTALL CURB AND GUTTER
L.INSTALL PAVEMENTS AND WALKS
M.FINAL GRADE SITE
N.SEED AND MULCH
O.WHEN ALL CONSTRUCTION ACTIVITY IS COMPLETE AND THE SITE IS STABILIZED,
REMOVE SILT FENCE AND RESEED ANY AREAS DISTURBED BY THE REMOVAL.
3.SITE DATA:
AREA OF DISTURBANCE (VS PROPERTY AREA ON C2-1):1.44± AC
PRE-CONSTRUCTION IMPERVIOUS AREA:1.10 AC
POST-CONSTRUCTION IMPERVIOUS AREA:0.93 AC
GENERAL SOIL TYPE:SEE GEOTECHNICAL REPORT BY BRAUN INTERTEC DATED
JULY 27, 2026.
4.THE LOCATION OF AREAS NOT TO BE DISTURBED MUST BE IDENTIFIED WITH FLAGS,
STAKES, SIGNS, SILT FENCE, ETC. BEFORE CONSTRUCTION BEGINS.
5.ALL DISTURBED GROUND LEFT INACTIVE FOR SEVEN (7) OR MORE DAYS SHALL BE
STABILIZED BY SEEDING OR SODDING (ONLY AVAILABLE PRIOR TO SEPTEMBER 15) OR
BY MULCHING OR COVERING OR OTHER EQUIVALENT CONTROL MEASURE.
6.ON SLOPES 3:1 OR GREATER MAINTAIN SHEET FLOW AND MINIMIZE RILLS AND/OR
GULLIES, SLOPE LENGTHS CAN NOT BE GREATER THAN 75 FEET.
DENOTES SLOPES GREATER THAN 3:1. ALL 3:1 SLOPES TO BE STABILIZED WITH
EROSION CONTROL BLANKET
7.ALL STORM DRAINS AND INLETS MUST BE PROTECTED UNTIL ALL SOURCES OF
POTENTIAL DISCHARGE ARE STABILIZED.
8.TEMPORARY SOIL STOCKPILES MUST HAVE EFFECTIVE SEDIMENT CONTROL AND CAN
NOT BE PLACED IN SURFACE WATERS OR STORM WATER CONVEYANCE SYSTEMS.
TEMPORARY STOCKPILES WITHOUT SIGNIFICANT AMOUNT OF SILT, CLAY, OR
ORGANIC COMPOUNDS ARE EXEPMT EX: CLEAN AGGREGATE STOCK PILES,
DEMOLITION CONCRETE STOCKPILES, SAND STOCKPILES.
9.SEDIMENT LADEN WATER MUST BE DISCHARGED TO A SEDIMENTATION BASIN
WHENEVER POSSIBLE. IF NOT POSSIBLE, IT MUST BE TREATED WITH THE APPROPRIATE
BMP'S.
10.SOLID WASTE MUST BE DISPOSED OF PROPERLY AND MUST COMPLY WITH MPCA
DISPOSAL REQUIREMENTS.
11.EXTERNAL WASHING OF CONSTRUCTION VEHICLES MUST BE LIMITED TO A DEFINED
AREA OF THE SITE, RUNOFF MUST BE PROPERLY CONTAINED.
12.NO ENGINE DEGREASING IS ALLOWED ON SITE.
13.THE OWNER WHO SIGNS THE NPDES PERMIT APPLICATION IS A PERMITTEE AND IS
RESPONSIBLE FOR COMPLIANCE WITH ALL TERMS AND CONDITIONS OF THE PERMIT.
THE OPERATOR (CONTRACTOR) WHO SIGNS THE NPDES PERMIT APPLICATION IS A
PERMITTEE FOR ALL APPLICABLE CONSTRUCTION ACTIVITY REQUIREMENTS FOUND IN
SECTIONS 3, 4, 6-24 OF THE NPDES PERMIT AND IS JOINTLY RESPONSIBLE WITH THE
OWNER FOR COMPLIANCE WITH THOSE PORTIONS OF THE PERMIT.
14.TERMINATION OF COVERAGE-PERMITTEE(S) WISHING TO TERMINATE COVERAGE MUST
SUBMIT A NOTICE OF TERMINATION (NOT) TO THE MPCA. ALL PERMITTEE(S) MUST
SUBMIT A NOT WITHIN 30 DAYS AFTER ONE OR MORE OF THE FOLLOWING
CONDITIONS HAVE BEEN MET:
A.FINAL STABILIZATION, PER NPDES PERMIT SECTION 13 HAS BEEN ACHIEVED ON
ALL PORTIONS OF THE SITE FOR WHICH THE PERMITTEE IS RESPONSIBLE.
B.TRANSFER OF OWNERSHIP AS DESCRIBED IN THE PERMIT.
15. INSPECTIONS
A.INITIAL INSPECTION FOLLOWING SILT FENCE INSTALLATION BY CITY
REPRESENTATIVE IS REQUIRED.
B.EXPOSED SOIL AREAS: ONCE EVERY 7 DAYS AND WITHIN 24 HOURS
FOLLOWING A 0.5" OVER 24 HOUR RAIN EVENT.
C.STABILIZED AREAS: ONCE EVERY 30 DAYS
D.FROZEN GROUND: AS SOON AS RUNOFF OCCURS OR PRIOR TO RESUMING
CONSTRUCTION.
E.INSPECTION AND MAINTENANCE RECORDS MUST BE RETAINED FOR 3 YEARS
AFTER FILING OF THE NOTICE OF TERMINATION AND MUST INCLUDE: DATE
AND TIME OF ACTION, NAME OF PERSON(S) CONDUCTING WORK, FINDING OF
INSPECTIONS AND RECOMMENDATIONS FOR CORRECTIVE ACTION, DATE AND
AMOUNT OF RAINFALL EVENTS GREATER THAN 0.5 INCHES IN A 24 HOUR
PERIOD.
16. MINIMUM MAINTENANCE
A.SILT FENCE TO BE REPAIRED, REPLACED, SUPPLEMENTED WHEN
NONFUNCTIONAL, OR 1/3 FULL; WITHIN 24 HOURS
B.SEDIMENT BASINS DRAINED AND SEDIMENT REMOVED WHEN REACHES 1/2
STORAGE VOLUME. REMOVAL MUST BE COMPLETE WITHIN 72 HOURS OF
DISCOVERY.
C.SEDIMENT REMOVED FROM SURFACE WATERS WITHIN (7)SEVEN DAYS
D.CONSTRUCTION SITE EXITS INSPECTED, TRACKED SEDIMENT REMOVED WITH 24
HOURS.
E.PROVIDE COPIES OF EROSION INSPECTION RESULTS TO CITY ENGINEER FOR ALL
EVENTS GREATER THAN 12" IN 24 HOURS
17.THE SWPPP, INCLUDING ALL CHANGES TO IT, AND INSPECTIONS AND MAINTENANCE
RECORDS MUST BE KEPT AT THE SITE DURING CONSTRUCTION ACTIVITY BY THE
PERMITTEE(S) WHO HAVE OPERATIONAL CONTROL OF THE SITE.
18.OWNER MUST KEEP RECORDS OF ALL PERMITS REQUIRED FOR THE PROJECT, THE
SWPPP, ALL INSPECTIONS AND MAINTENANCE, PERMANENT OPERATION AND
MAINTENANCE AGREEMENTS, AND REQUIRED CALCULATIONS FOR TEMPORARY AND
PERMANENT STORM WATER MANAGEMENT SYSTEMS. THESE RECORDS MUST BE
RETAINED FOR THREE YEARS AFTER FILING NPDES NOTICE OF TERMINATION.
19.SWPPP MUST BE AMENDED WHEN:
A.THERE IS A CHANGE IN DESIGN, OPERATION, MAINTENANCE, WEATHER OR
SEASONAL CONDITIONS THAT HAS A SIGNIFICANT EFFECT ON DISCHARGE
B.INSPECTIONS INDICATE THAT THE SWPPP IS NOT EFFECTIVE AND DISCHARGE IS
EXCEEDING WATER QUALITY STANDARDS.
C.THE BMP'S IN THE SWPPP ARE NOT CONTROLLING POLLUTANTS IN DISCHARGES
OR IS NOT CONSISTENT WITH THE TERMS AND CONDITIONS OF THE PERMIT.
20.CONCRETE WASHOUT AREA
A.CONCRETE WASH-OUT IS NOT ALLOWED ON-SITE.
21.IN THE EVENT OF ENCOUNTERING A WELL OR SPRING DURING CONSTRUCTION
CONTRACTOR TO CEASE CONSTRUCTION ACTIVITY AND NOTIFY ENGINEER.
22.PIPE OULTETS MUST BE PROVIDED WITH TEMPORARY OR PERMANENT ENERGY
DISSIPATION WITHIN 24 HOURS AFTER CONNECTION TO A SURFACE WATER.
23.FINAL STABILIZATION
FINAL STABILIZATION REQUIRES THAT ALL SOIL DISTURBING ACVTIVITIES HAVE BEEN
COMPLETED AND THAT DISTURBED AREAS ARE STABILIZED BY A UNIFORM PERENNIAL
VEGETATIVE COVER WITH 70% OF THE EXPECTED FINAL DENSITY, AND THAT ALL
PERMANENT PAVEMENTS HAVE BEEN INSTALLED. ALL TEMPORARY BMP'S SHALL BE
REMOVED, DITCHES STABILIZED, AND SEDIMENT SHALL BE REMOVED FROM
PERMANENT CONVEYANCES AND SEDIMENTATION BASINS IN ORDER TO RETURN THE
POND TO DESIGN CAPACITY.
24. TEMPORARY SEDIMENTATION BASINS
A.THE TEMPORARY SEDIMENTATION BASINS SHALL BE CONSTRUCTED AND MADE
OPERATIONAL PRIOR TO DISTURBANCE OF 10 OR MORE ACRES DRAINING TO A
COMMON LOCATION.
B.TEMPORARY SEDIMENTATION BASINS ARE REQUIRED PRIOR TO RUNOFF
LEAVING THE CONSTRUCTION SITE OR ENTERING SURFACE WATERS WHEN 10
OR MORE ACRES OF DISTURBED SOILS DRAIN TO A COMMON LOCATION. THE
BASIN MUST PROVIDE 3,600 CUBIC FEET OF STORAGE BELOW THE OUTLET PER
ACRE DRAINED. IF HYDRAULIC CALCULATIONS ARE AVAILABLE, THE TEMPORARY
SEDIMENTATION BASIN MUST PROVIDE A STORAGE VOLUME EQUIVALENT TO
THE 2-YEAR, 24-HOUR STORM, BUT IN NO CASE LESS THAN 1800 CUBIC FEET PER
ACRE DRAINED. THE TEMPORARY SEDIMENTATION BASIN MUST BE
CONSTRUCTED AND MADE OPERATIONAL CONCURRENT WITH THE START OF
SOIL DISTURBANCE UP GRADIENT OF THE POND. THE TEMPORARY
SEDIMENTATION BASIN SHALL BE DESIGNED TO PREVENT SHORT
CIRCUITING. THE OUTFALL SHALL BE DESIGNED TO REMOVE FLOATABLE DEBRIS,
ALLOW FOR COMPLETE DRAWDOWN OF THE POND FOR MAINTENANCE
ACTIVITIES, AND HAVE ENERGY DISSIPATION. THE EMERGENCY SPILLWAY SHALL
BE STABILIZED.
C.TEMPORARY SEDIMENTATION BASINS SHALL BE SITUATED OUTSIDE OF SURFACE
WATERS AND ANY REQUIRED BUFFER ZONE, AND MUST BE DESIGNED TO
AVOID DRAINING WETLANDS, UNLESS THE IMPACT IS IN COMPLIANCE WITH
THE REQUIREMENTS OF THIS PERMIT.
D.EXCESSIVE SEDIMENT-LADEN WATER THAT IS NOT PROPERLY FILTERED WILL NOT
BE PERMITTED TO DISCHARGE FROM SITE.
25.DEWATERING AND BASIN DRAINING
A.TURBID OR SEDIMENT-LADEN WATERS RELATED TO DEWATERING OR BASIN
DRAINING SHALL BE DISCHARGED TO A TEMPORARY OR PERMANENT
SEDIMENTATION BASIN ON THE PROJECT SITE UNLESS INFEASIBLE. THE
TEMPORARY OR PERMANENT BASIN MAY DISCHARGE TO SURFACE WATERS IF
THE BASIN WATER HAS BEEN VISUALLY CHECKED TO ENSURE ADEQUATE
TREATMENT HAS BEEN OBTAINED IN THE BASIN AND THAT THE NUISANCE
CONDITIONS WILL NOT RESULT FROM THE DISCHARGE. DISCHARGE POINTS
SHALL BE ADEQUATELY PROTECTED FROM EROSION AND PROPER VELOCITY
DISSIPATION PROVIDED.
B.ALL WATER FROM DEWATERING OR BASIN-DRAINING ACTIVITIES MUST BE
DISCHARGED IN A MANNER THAT DOES NOT CAUSE NUISANCE CONDITIONS,
EROSION IN THE RECEIVING CHANNELS OR ON DOWN SLOPE PROPERTIES, OR
INUNDATION IN WETLANDS CAUSING SIGNIFICANT ADVERSE IMPACTS TO THE
WETLAND.
C.IF FILTERS WITH BACKWASH WATERS ARE USED, THE BACKWASH WATER SHALL
BE HAULED AWAY FOR DISPOSAL, RETURNED TO THE BEGINING OF THE
TREATMENT PROCESS, OR INCORPORATED INTO SITE IN A MANNER THAT DOES
NOT CAUSE EROSION. BACKWASH WATER MAY BE DISCHARGED TO SANITARY
SEWER IF PERMISSION IS GRANTED BY THE SANITARY SEWER AUTHORITY.
26.POLLUTION PREVENTION
A.BUILDING PRODUCTS THAT HAVE THE POTENTIAL TO LEACH POLLUTANTS
MUST BE UNDER COVER TO PREVENT DISCHARGE OR PROTECTED BY AN
EFFECTIVE MEANS DESIGNED TO MINIMIZE CONTACT WITH STORMWATER.
B.PESTICIDES, HERBICIDES, INSECTICIDES, FERTILIZERS, TREATMENT CHEMICALS,
AND LANDSCAPE MATERIALS MUST BE UNDER COVER.
C.HAZARDOUS MATERIALS AND TOXIC WASTE MUST BE PROTECTED TO PREVENT
VANDALISM.
D.SOLID WASTE MUST BE STORED, COLLECTED AND DISPOSED OF IN COMPLIANCE
WITH MINN. R. CH 7035.
E.PORTABLE TOILETS MUST BE POSITIONED SO THAT THEY ARE SECURE AND WILL
NOT BE TIPPED OR KNOCKED OVER. SANITARY WASTE MUST BE DISPOSED OF
PROPERLY IN ACCORDANCE WITH MINN. R. CH 7041.
F.DISCHARGE OF SPILLED OR LEAKED CHEMICALS, INCLUDING FUEL, FROM ANY
AREA WHERE CHEMICALS OR FUEL WILL BE LOADED OR UNLOADED SHALL BE
PREVENTED USING DRIP PANS OR ABSORBENTS. SUPPLIES SHALL BE AVAILABLE
AT ALL TIMES TO CLEAN UP DISCHARGED MATERIALS AND THAT AN
APPROPRIATE DISPOSAL METHOD MUST BE AVAILABLE FOR RECOVERED SPILLED
MATERIALS.
27. DESIGN CALCULATIONS
TEMPORARY & PERMANENT STORMWATER TREATMENT ARE DESIGNED TO MEET MPCA
GENERAL & SPECIAL WATER REQUIREMENTS. CALCULATIONS ARE PART OF THE
HYDROLOGY REPORT, WHICH IS TO BE CONSIDERED PART OF THE SWPP
DOCUMENTS. SEE HYDROLOGY REPORT FOR ADDITIONAL INFORMATION.
28.GENERAL STORMWATER DISCHARGE REQUIREMENTS
ALL REQUIREMENTS LISTED IN SECTIONS 5-7, 14, 16-19, 21, 24 OF THE PERMIT FOR
DESIGN OF THE PERMANENT STORMWATER MANAGEMENT SYSTEM AND DISCHARGE
HAVE BEEN INCLUDED IN THE PREPARATION OF THIS SWPP. THESE INCLUDE BUT ARE
NOT LIMITED TO:
A.THE EXPECTED AMOUNT, FREQUENCY, INTENSITY, AND DURATION
PRECIPITATION.
B.THE NATURE OF STORMWATER RUNOFF AND RUN-ON AT THE SITE.
C.PEAK FLOW RATES AND STORWATER VOLUMES TO MINIMIZE EROSION AT
OUTLETS AND DOWNSTREAM CHANNEL AND STREAM BANK EROSION.
D.THE RANGE OF SOIL PARTICLE SIZES EXPECTED TO BE PRESENT ON THE SITE.
29.CONSTRUCTION OF FILTRATION BASINS
A.NO HEAVY TRAFFIC ON FILTRATION AREAS. CONSTRUCTION TO BE DONE WITH
MINIMAL COMPACTION TO FILTRATION AREAS. IF COMPACTION IS
ENCOUNTERED, BASIN SOILS FOR THE FIRST & MUST BE REMOVED & RELAID.
B.INFILTRATION SYSTEMS MUST NOT BE EXCAVATED TO FINAL GRADE UNTIL THE
CONTRIBUTING DRAINAGE AREA HAD BEEN CONSTRUCTED AND FULLY
STABILIZED UNLESS RIGOROUS EROSIN PREVENTION AND SEDIMENT CONTROLS
ARE PROVIDED( SECTION 16.4).
C.WHEN AN INFILTRATION SYSTEM IS EXCAVATED TO FINAL GRADE (OR WITHIN
THREE (3) FEET OF FINAL GRADE), THE PERMITTEE(S) MUST EMPLOY RIGOROUS
EROSION PREVENTION AND SEDIMENT CONTROLS (E.G., DIVERSION BERMS) TO
KEEP SEDIMENT AND RUNOFF COMPLETELY AWAY FROM THE INFILTRATION
AREA. THE AREA MUST BE STAKED OFF AND MARKED SO THAT HEAVY
CONSTRUCTION VEHICLES OR EQUIPMENT WILL NOT COMPACT THE SOIL IN
THE PROPOSED INFILTRATION AREA.
D.TO PREVENT CLOGGING OF THE INFILTRATION OR FILTRATION SYSTEM, THE
PERMITTEE(S) MUST USE A PRETREATMENT DEVICE SUCH AS A VEGETATED FILTER
STRIP, SMALL SEDIMENTATION BASIN, OR WATER QUALITY INLET (E.G., GRIT
CHAMBER) TO SETTLE PARTICULATES BEFORE THE STORMWATER DISCHARGES
INTO THE INFILTRATION OF FILTRATION SYSTEM.
30.POST CONSTRUCTION
THE WATER QUALITY VOLUME THAT MUST BE RETAINED ON SITE BY THE PROJECT'S
PERMANENT STORMWATER MANAGEMENT SYSTEM DESCRIBED IN SECTION 15
SHALL BE ONE (1) INCH OF RUNOFF FROM THE NEW IMPERVIOUS SURFACES CREATED
BY THE PROJECT. SEE SECTION 15. FOR MORE INFORMATION ON INFILTRATION
DESIGN, PROHIBITIONS AND APPROPRIATE SITE CONDITIONS.
31.RESPONSIBILITIES
A.THE OWNER MUST IDENTIFY A CONTRACTOR WHO WILL OVERSEE THE SWPPP
IMPLEMENTATION AND THE PERSON RESPONSIBLE FOR INSPECTION AND
MAINTENANCE:
B.THE OWNER MUST IDENTIFY THE A PERSON WHO WILL BE RESPONSIBLE FOR
LONG TERM OPERATIONS AND MAINTENANCE OF THE PERMANENT
STORMWATER MANAGEMENT SYSTEM:
32.TRAINING REQEMENTS
THE PERMITTES(S) SHALL ENSURE THE FOLLOWING INDIVIDUALS IDENTIFIED IN THIS
PART HAVE BEEN TRIANED IN ACCORDANCE WITH THIS PERMIT'S TRAINING
REQUIREMENTS.
1. WHO MUST BE TRAINED:
A. INDIVIDUAL(S) PREPARING THE SWPPP FOR THE PROJECT
B. INDIVIDUAL(S) OVERSEEING IMPLEMENTATION OF, REVISING, AND/OR
AMENDING THE SWPPP AND INDIVIDUALS(S) PERFORMING
INSPECTIONS FOR THE PROJECT. ONE OF THESE
INDIVDUAL(S) MUST BE AVAILABLE FOR AN ONSITE INSPECTION
WITHIN 72 HOURS UPON REQUEST BY THE MPCA.
C.INDIVIDUAL(S) PERFORMING OR SUPERVISING THE INSTALLATION,
MAINTENANCE AND REPAIR OF BMPS. AT LEAST ONE INDIVIDUAL ON A PROJECT
MUST BE TRAINED IN THES JOB DUTIES.
2.TRAINING CONTENT:
THE CONTENT AND EXTENT OF TRAINING MUST BE COMMENSURATE
WITH THE INDIVIDUAL'S JOB DUTIES AND RESPONSIBILITIES WITH REGARD
TO ACTIVITIES COVERED UNDER THIS PERMIT FOR THE PROJECT. AT LEAST
ONE INDIVIDUAL PRESENT ON THE PERMITTED PROJECT SITE (OR
AVAVILABLE TO THE PROJECT SITE IN 72 HOURS) MUST BE TRAINED IN THE
JOB DUTIES DESCRIBED IN SECTION 21.2B AND SECTION 21.2C.
33.THE PERMITTEE(S) SHALL ENSURE THAT THE INDIVIDUALS ARE TRAINED BY LOCAL,
STATE, FEDERAL AGENCIES, PROFESSIONAL OR OTHER ENTITIES WITH EXPERTISE IN
EROSION PREVENTION, SEDIMENT CONTROL, PERMANENT STORMWATER
MANAGEMENT AND THE MINNESOTA NPDES/SDS CONSTRUCTION STORMWATER
PERMIT. AN UPDATE REFESHER-TREINING MUST BE ATTENDED EVERY THREE (3) YEARS
STARTING THREE (3) YEARS FROM THE ISSUANCE DATE OF THIS PERMIT.
33.LIST OF CONTACTS
* MPCA 24HR. HAZARDOUS SPILL HOTLINE: 651-649-5457 OF 80420798
DESCRIPTION UNIT
TEMPORARY ROCK CONSTRUCTION ENTRANCE EA
PREFABRICATED CONCRETE WASHOUT EA
SILT FENCE (STANDARD)LF
BIO-ROLL LF
INLET PROTECTION EA
QUANTITY
1
NOT ALLOWED
645
-
8
TITLE NAME
OWNER REP.PATRICK MCCANN
COMPANY PHONE NUMBER
BLAZE
PROJECT MANAGER BRIAN JOHNSON LOUCKS 763-496-6745
ENGINEER SWPPP BRIAN JOHNSON 763-496-6745LOUCKS
CONTRACTOR
SITE MANGER
651-641-2106
SWPPP NOTES
ESTIMATED QUANTITIES
CERTIFICATION
VICINITY MAP CONSTRUCTION STORMWATER SPECIAL WATERS SEARCH MAP
EROSION CONTROL FABRIC SY 184
GREINER CONSTRUCTION
GREINER CONSTRUCTION
NO PARKING
PROPOSED
CREDIT UNION
5,050 SF
FFE-949.25DO NOT ENTERFFE=949.25
SAN STUB#102
INV=938.99 (6") E
SAN MH#101
RIM=948.26
INV=938.88 (6") W
INV=936.88 (6") S
21 LF 6" PVC
SAN @ 0.51%
4
444490 LF 6" PVC
SAN @ 0.71%
SAN STUB#100
INV=936.24 (6") N
INV=935.64 (FIELD VERIFY)8888888
8 88888 8 88
88888888
8
8
86" FIRE SERVICE.
COORDINATE EXACT
LOCATION AND INVERT
WITH MECHANICAL.
2" DOMESTIC SERVICE.
COORDINATE EXACT
LOCATION AND INVERT
WITH MECHANICAL.
CONNECT TO EXISTING WATERMAIN
WITH 6" C900 FIRE SERVICE AND
GATE VALVE & 2" HPDE DOMESTIC
SERVICE AND GATE VALVE PER CITY
STANDARDS.
VERIFY EXACT LOCATION AND
INVERT OF EXISTING WATER MAIN.
226 LF -6" C900
FIRE SERVICE231 LF - 2" HDPE
DOMESTIC SERVICE
FIRE DEPARTMENT
CONNECTION
141'-FDC TO HYDRANT
COORDINATE FIBER & POWER
WITH UTILIT PROVIDERS &
SITE ELECTRICAL PLAN
11'
12'
90° BENDS
22.5° BENDS
67.5° BENDS
LOUCKS
W:\2026\260351\CADD DATA\CIVIL\_dwg Sheet Files\C4-1 SANITARY AND WATERMAIN PLAN12755 Highway 55, Suite R100
Plymouth, MN 55441
763.424.5505
www.loucksinc.com
PLANNING
CIVIL ENGINEERING
LAND SURVEYING
LANDSCAPE ARCHITECTURE
ENVIRONMENTAL
C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e
instruments of the Consultant professional services for use solely
with respect to this project. These CADD files shall not be used
on other projects, for additions to this project, or for completion
of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he
C onsultant . With t he Cons ultant's appr oval, ot hers may be
per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or
information and reference only. All intentional or unintentional
revisions, additions, or deletions to these CADD files shall be
made at the full risk of that party making such revisions, additions
or deletions and that party shall hold harmless and indemnify the
Consultant from any & all responsibilities, claims, and liabilities.
CADD QUALIFICATION
QUALITY CONTROL
PROFESSIONAL SIGNATURE
SUBMITTAL/REVISIONS
BLAZE
CREDIT UNION
CHANHASSEN
320 Lake Drive East
Chanhassen, MN 55317
2025 Larpenteur Ave. W.
Falcoln Heights, MN 55113
C1-1 DEMOLITION PLAN
C2-1 SITE PLAN
C3-1 GRADING PLAN
C3-2 SWPPP
C3-2 SWPPP NOTES
C4-1 SANITARY AND WATERMAIN PLAN
C4-2 STORM SEWER PLAN
C8-1 CIVIL DETAILS
C8-2 CIVIL DETAILS
L0-1 TREE REPLACEMENT PLAN
L1-1 LANDSCAPE PLAN
L2-1 LANDSCAPE DETAILS
10/02/26 ENTITLEMENTS SUBMITTAL
License No.
Date
I hereby certify that this plan, specification or report was
prepared by me or under my direct supervision and that
I am a duly Licensed Professional Engineer under the
laws of the State of Minnesota.
46607
10/02/26
Brian M. Johnson - PE
Review Date
Project Lead
Drawn By
Checked By
Loucks Project No.
10/02/26
BMJ
BMJ
BMJ
260351
N
SCALE IN FEET
0 20 40
SANITARY
AND
WATERMAIN
PLAN
C4-1
TOLL FREE: 1-800-252-1166
TWIN CITY AREA: 651-454-0002
Gopher State One Call
CALL BEFORE YOU DIG!
WARNING:
THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL
EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN
MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES.
THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT
LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES,
CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE
DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED
DURING CONSTRUCTION AT NO COST TO THE OWNER.
1. ALL PLUMBING SHALL BE INSTALLED IN ACCORDANCE WITH THE 2020 MN PLUMBING CODE, MN RULES, CHAPTER 4714. ALL PIPE, FITTINGS, TRAPS,
FIXTURES, MATERIALS, AND DEVICES SHALL BE LISTED OR LABELED BY A THIRD-PARTY LISTING AGENCY AND COMPLY WITH THE APPLICABLE
STANDARDS REFERENCED IN THE CODE (SEE SECTIONS 301.2 AND 1701.1).
2.ALL UTILITY PIPE BEDDING SHALL BE COMPACTED SAND OR FINE GRANULAR MATERIAL. ALL COMPACTION SHALL BE PERFORMED PER THE
REQUIREMENTS OF THE CEAM SPECIFICATION AND THE GEOTECHNICAL REPORT BY BRAUN INTERTEC DATED ****pending****.
3.ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE PERFORMED PER THE REQUIREMENTS OF THE STATE AND LOCAL JURISDICTIONS. THE CITY
DEPARTMENT OF ENGINEERING AND BUILDING INSPECTIONS DEPARTMENT AND THE CONSTRUCTION ENGINEER MUST BE NOTIFIED AT LEAST 48
HOURS PRIOR TO ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, OR WORK IMPACTING PUBLIC UTILITIES.
4.ALL SANITARY SEWER AND WATER SERVICES SHALL TERMINATE 5' FROM THE BUILDING FACE UNLESS OTHERWISE NOTED.
5.A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATION IS REQUIRED FOR ALL UTILITIES UNLESS OTHERWISE
NOTED.
6.ALL NEW WATERMAIN AND SERVICES MUST HAVE A MINIMUM OF 7.5 FEET OF COVER. EXTRA DEPTH MAY BE REQUIRED TO MAINTAIN A MINIMUM
18" VERTICAL SEPARATION TO SANITARY OR STORM SEWER LINES. THE CONTRACTOR SHALL FIELD ADJUST WATERMAIN TO AVOID CONFLICTS WITH
SANITARY SEWER, STORM SEWER, AND SERVICES AS REQUIRED. INSULATION OF WATER AND SANITARY SEWER LINES SHALL BE PROVIDED WHERE 7.5
FEET MINIMUM DEPTH CAN NOT BE ATTAINED.
7.ALL FIRE HYDRANTS SHALL BE LOCATED 5 FEET BEHIND BACK OF CURB OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED.
8.ALL STREET REPAIRS AND PATCHING SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CITY. ALL TRAFFIC CONTROL SHALL BE PROVIDED BY
THE CONTRACTOR AND SHALL BE ESTABLISHED PER THE REQUIREMENTS OF THE MINNESOTA MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES
(MMUTCD) AND THE CITY. THIS SHALL INCLUDE ALL SIGNAGE, BARRICADES, FLASHERS AND FLAGGERS AS NEEDED. ALL PUBLIC STREETS SHALL BE
OPEN TO TRAFFIC AT ALL TIMES. NO ROAD CLOSURES SHALL BE PERMITTED WITHOUT THE EXPRESSED AUTHORITY OF OF THE CITY.
9.THE CITY SHALL OPERATE ALL GATE VALVES IN PUBLIC RIGHT-OF-WAY.
10.CONNECTIONS TO EXISTING MANHOLES SHALL BE MADE BY CORE DRILLING THE MANHOLE AT THE PROPOSED INVERT ELEVATIONS AND INSTALLING
A RUBBER BOOT. GROUT IN THE BOOT AND AN INVERT FOR THE NEW SEWER LINE.
11.PIPE LENGTHS SHOWN ON THE PLAN INCLUDE THE APRON SECTION.
12.TRENCH COMPACTION SHALL BE 95% STANDARD PROCTOR DENSITY IN THE AREA FROM THE PIPE ZONE TO WITHIN 3 FEET OF FINISHED GRADE AND
100% IN FINAL 3 FEET OF THE BACKFILL TO FINISH GRADE.
13.WHERE SEWER CROSSES WATER MAIN, THE PVC MUST COMPLY WITH ASTM D1785, D2665, F891, F1488, OR F1760 WHEN ABOVE OR LESS THAN 12
INCHES BELOW THE WATER. SOLVENT WELDED JOINTS MUST USE ASTM F656 PURPLE PRIMER AND ASTM D2564 CEMENT. THE SEWER MUST BE
INSTALLED PER SECTION 314.4.1. THERE SHALL BE NO JOINTS OR CONNECTIONS WITHIN 10 FEET OF ANY CROSSING.
14.THE WATER SERVICE PIPE SHALL MEET ASTM D2239, ASTM D2737, ASTM D3035, AWWA C901, OR CSA B137.1. JOINTS AND FITTINGS MUST BE
INSTALLED PER THE MANUFACTURER’S INSTRUCTIONS AND BE HEAT FUSED OR USE APPROVED INSERT FITTINGS WITH STAINLESS STEEL CLAMPS (SEE
TABLE 604.1 AND SECTION 605.6). COMPRESSION FITTINGS MAY BE USED ONLY IF EVIDENCE OF THIRD-PARTY LISTING TO CSA STANDARD B137.1 BY
AN ACCREDITED LISTING AGENCY IS PROVIDED TO THE PLUMBING INSPECTOR. AN ACCESSIBLE BLUE 14 AWG MINIMUM TRACER WIRE SUITABLE FOR
DIRECT BURY MUST BE PROVIDED (SEE SECTION 604.10.1). THE SAME TRACER WIRE REQUIREMENT ALSO APPLIES TO THE 6-INCH AWWA C900
WATERMAIN.
15.INLET AND OUTLET CONNECTIONS TO SEWER MANHOLES MUST USE FLEXIBLE COMPRESSION JOINTS LOCATED BETWEEN 12 AND 36 INCHES FROM
THE MANHOLE OR APPROVED RESILIENT RUBBER JOINTS MUST BE USED TO MAKE WATERTIGHT CONNECTIONS TO MANHOLES, CATCH BASINS, AND
OTHER STRUCTURES (SEE SECTION 719.6).
16.MATERIALS USED FOR SUBSOIL DRAINS MUST COMPLY WITH TABLE 1101.4.6. POLYETHYLENE PIPE MUST MEET ASTM F667 AND PVC PIPE MUST MEET
ASTM D2729. ALTERNATE MATERIALS MAY BE USED IF APPROVED BY THE ADMINISTRATIVE AUTHORITY PRIOR TO INSTALLATION (SEE SECTION 301.3).
17.CONNECTIONS OF DOWNSPOUT GUTTERS TO STORM SEWER LEADERS SHALL BE BY INDIRECT AIR GAP OR AIR BREAK, OTHERWISE THE GUTTER SHALL
BE OPEN FACED.
18.A CLEANOUT IS REQUIRED NEAR THE CONNECTION OF THE BUILDING DRAIN AND BUILDING SEWER (SEE SECTION 719.1).
19.THE PLUMBING SYSTEM SHALL BE TESTED IN ACCORDANCE WITH SECTIONS 609.4 AND 712.0.
UTILITY NOTES
PARKING STALL COUNT
ACCESSIBLE PARKING STALL
2
LEGEND
CATCH BASIN
STORM SEWER
SANITARY SEWER
WATERMAIN
STORM MANHOLE
SANITARY MANHOLE
HYDRANT
GATE VALVE
SPOT ELEVATION
SIGN
LIGHT POLE
POWER POLE
WATER MANHOLE / WELL
CONTOUR
CONCRETE CURB
UNDERGROUND ELECTRIC
CONCRETE
TELEPHONE PEDESTAL
UNDERGROUND TELEPHONE
UNDERGROUND GAS
OVERHEAD UTILITY
CHAIN LINK FENCE
BUILDING
RETAINING WALL
NO PARKING
UNDERGROUND FIBER OPTIC
SANITARY SEWER SERVICE
WATER SERVICE
ELECTRIC METER
GAS METER
TREE LINE
EXISTING PROPOSED
972
DRAINTILE
373PARKING SETBACK LINE
BUILDING SETBACK LINE
2
FENCE
FLARED END SECTION
POST INDICATOR VALVE
BENCHMARK
SOIL BORING
3DIRECTION OF FLOW 1.0%
972.5
NO PARKING
PROPOSED
CREDIT UNION
5,050 SF
FFE-949.25DO NOT ENTERFFE=949.25
4
44448888888
8
CB#109
RIM=947.50
INV=943.67 (8") W
INV=943.27 (12") S
CBMH#108
RIM=947.46
INV=943.32 (8") NW
INV= 942.92 (12") N
INV=942.72 (15") S
CBMH#107
RIM=947.07
INV= 942.66 (15") N
INV=942.66 (15") SW
CBMH#106
RIM=947.48
INV=943.04 (8") N
INV= 942.44 (15") NE
INV=942.24 (18") W
SUMP=939.24
CB#140
RIM=947.04
INV=943.38 (8") NE
INV=942.98 (12") E
STMH#104
RIM=948.04
INV=943.14 (8") NE
INV= 942.74 (12") W
INV=942.74 (12") E
SUMP=939.74
79 LF 12"
HDPE @ 0.44%
20 LF 15"
HDPE @ 0.32%
68 LF 15" C-900
PVC @ 0.32%
16 LF 18"
HDPE @ 0.25%56 LF 12"
HDPE @ 0.44%
IRRIGATION REUSE CISTERN
CITY WATER BODY ID 10-0001-00
72" DUROMAXX INV=930.70
6" ROCK INV=930.20
HWL=943.52
STMH#101
RIM=947.81
INV= 939.97 (15") E
INV= 935.70 (12") W
INV=939.75 (18") S
9 LF 15"
HDPE @ 0.50%
ST STUB#102
INV=940.02 (15") W88 888 8 88
88888888
8
8
8ST STUB#202
INV=936.70 (12") W
23 LF 12"
HDPE @ 4.31%
STMH#201
RIM=947.85
INV= 935.70 (12") E
14 LF 12"
HDPE @ 0.00%
W/BACKFLOW PREVENTOR
ST STUB#200
INV=935.70 (12") E
9 LF 12"
HDPE @ 0.44%
ST STUB#103
INV= 942.70 (12") W
ST STUB#105
INV= 942.20 (18") E
UNDERGROUND FILTRATION
DNR WATER BODY ID 10-0001-00
84" CMP INV=936.70
6" ROCK INV=936.20
HWL=943.52
C-900 STORM PIPE
OVER WATER CROSSING
DOWN SPOUT CONNECTION
RIM=949.00
INV=947.25
DOWN SPOUT CONNECTION
RIM=949.00
INV=946.50
DOWN SPOUT CONNECTION
RIM=948.65
INV=946.15
WYE & CLEANOUT
INV=946.69
WYE & CLEANOUT
INV=947.22
WYE
INV=944.62
WYE
INV=944.16 WYE
INV=944.09
WYE & CLEANOUT
INV=944.07
WYE
INV=943.98
111 LF 8" STORM
@ 2.08%
31 LF 8" STORM
@ 6.01%
26 LF 8" STORM
@ 2.08%
54 LF 8" STORM
@ 6.27%
58 LF 8" STORM
@ 5.99%
36 LF 8" STORM
@ 2.08%
61 LF 8" STORM
@ 2.08%
18 LF 8" STORM (2)
@ 11.50%
5 LF 8" STORM
@ 41.60%
8 LF 8" STORM
@ 27.13%
7 LF 6" DRAINTILE
@ 2.08%
67 LF 6" DRAINTILE
@ 2.08%
VERIFY UTILITY PROVIDER
PREFERRED HANDHOLE LOCAITON
VERIFY UTILITY PROVIDER
PREFERRED HANDHOLE LOCAITON
WYE
INV=945.63
INV=947.02
INV=945.09
DOWN SPOUT CONNECTION
RIM=949.00
INV=944.94
LOUCKS
W:\2026\260351\CADD DATA\CIVIL\_dwg Sheet Files\C4-2 STORM SEWER PLAN12755 Highway 55, Suite R100
Plymouth, MN 55441
763.424.5505
www.loucksinc.com
PLANNING
CIVIL ENGINEERING
LAND SURVEYING
LANDSCAPE ARCHITECTURE
ENVIRONMENTAL
C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e
instruments of the Consultant professional services for use solely
with respect to this project. These CADD files shall not be used
on other projects, for additions to this project, or for completion
of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he
C onsultant . With t he Cons ultant's appr oval, ot hers may be
per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or
information and reference only. All intentional or unintentional
revisions, additions, or deletions to these CADD files shall be
made at the full risk of that party making such revisions, additions
or deletions and that party shall hold harmless and indemnify the
Consultant from any & all responsibilities, claims, and liabilities.
CADD QUALIFICATION
QUALITY CONTROL
PROFESSIONAL SIGNATURE
SUBMITTAL/REVISIONS
BLAZE
CREDIT UNION
CHANHASSEN
320 Lake Drive East
Chanhassen, MN 55317
2025 Larpenteur Ave. W.
Falcoln Heights, MN 55113
C1-1 DEMOLITION PLAN
C2-1 SITE PLAN
C3-1 GRADING PLAN
C3-2 SWPPP
C3-2 SWPPP NOTES
C4-1 SANITARY AND WATERMAIN PLAN
C4-2 STORM SEWER PLAN
C8-1 CIVIL DETAILS
C8-2 CIVIL DETAILS
L0-1 TREE REPLACEMENT PLAN
L1-1 LANDSCAPE PLAN
L2-1 LANDSCAPE DETAILS
10/02/26 ENTITLEMENTS SUBMITTAL
License No.
Date
I hereby certify that this plan, specification or report was
prepared by me or under my direct supervision and that
I am a duly Licensed Professional Engineer under the
laws of the State of Minnesota.
46607
10/02/26
Brian M. Johnson - PE
Review Date
Project Lead
Drawn By
Checked By
Loucks Project No.
10/02/26
BMJ
BMJ
BMJ
260351
N
SCALE IN FEET
0 20 40
STORM SEWER
PLAN
C4-2TOLL FREE: 1-800-252-1166
TWIN CITY AREA: 651-454-0002
Gopher State One Call
CALL BEFORE YOU DIG!
WARNING:
THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL
EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN
MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES.
THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT
LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES,
CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE
DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED
DURING CONSTRUCTION AT NO COST TO THE OWNER.
PARKING STALL COUNT
ACCESSIBLE PARKING STALL
2
LEGEND
CATCH BASIN
STORM SEWER
SANITARY SEWER
WATERMAIN
STORM MANHOLE
SANITARY MANHOLE
HYDRANT
GATE VALVE
SPOT ELEVATION
SIGN
LIGHT POLE
POWER POLE
WATER MANHOLE / WELL
CONTOUR
CONCRETE CURB
UNDERGROUND ELECTRIC
CONCRETE
TELEPHONE PEDESTAL
UNDERGROUND TELEPHONE
UNDERGROUND GAS
OVERHEAD UTILITY
CHAIN LINK FENCE
BUILDING
RETAINING WALL
NO PARKING
UNDERGROUND FIBER OPTIC
SANITARY SEWER SERVICE
WATER SERVICE
ELECTRIC METER
GAS METER
TREE LINE
EXISTING PROPOSED
972
DRAINTILE
373PARKING SETBACK LINE
BUILDING SETBACK LINE
2
FENCE
FLARED END SECTION
POST INDICATOR VALVE
BENCHMARK
SOIL BORING
3DIRECTION OF FLOW 1.0%
972.5
1. ALL STORM SEWER UTILITIES SHALL BE FURNISHED AND INSTALLED PER THE REQUIREMENTS OF THE
SPECIFICATIONS,THE MINNESOTA PLUMBING CODE, THE LOCAL GOVERNING UNIT , AND THE STANDARD UTILITIES
SPECIFICATION OF THE CITY ENGINEERS ASSOCIATION OF MINNESOTA (CEAM), 2013 EDITION.
2.ALL UTILITY PIPE BEDDING SHALL BE COMPACTED SAND OR FINE GRANULAR MATERIAL. ALL COMPACTION SHALL BE
PERFORMED PER THE REQUIREMENTS OF THE CEAM SPECIFICATION AND THE GEOTECHNICAL REPORT BY BRAUN
INTERTEC DATED ****pending****.
3.ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE PERFORMED PER THE REQUIREMENTS OF THE STATE AND LOCAL
JURISDICTIONS. THE CITY DEPARTMENT OF ENGINEERING AND BUILDING INSPECTIONS DEPARTMENT AND THE
CONSTRUCTION ENGINEER MUST BE NOTIFIED AT LEAST 48 HOURS PRIOR TO ANY WORK WITHIN THE PUBLIC RIGHT
OF WAY, OR WORK IMPACTING PUBLIC UTILITIES.
4.ALL STORM SEWER SHALL TERMINATE 5' FROM THE BUILDING FACE UNLESS OTHERWISE NOTED.
5.A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATION IS REQUIRED FOR
ALL UTILITES UNLESS OTHERWISE NOTED.
6.ALL PORTIONS OF THE STORM SEWER SYSTEM, INCLUDING CATCH BASINS, LOCATED WITHIN 10 FEET OF THE
BUILDING OR WATER SERVICE LINE MUST BE TESTED ACCORDANCE WITH MINNESOTA RULES, PART 4715.2820
7.ALL JOINTS AND CONNECTIONS IN THE STORM SEWER SYSTEM SHALL BE GASTIGHT OR WATERTIGHT (SEE MINNESOTA
RULES, PART 4715.0700). APPROVED RESILIENT RUBBER JOINTS MUST BE USED TO MAKE WATERTIGHT CONNECTIONS
TO MANHOLES, CATCHBASINS, AND OTHER STRUCTURES.
8.THE FOLLOWING MATERIALS ARE ACCEPTABLE, IN ACCORDANCE WITH DoLI AND THE MN PLUMBING CODE, FOR
STORM SEWER APPLICATION:
8.1.DOWNSPOUT COLLECTION PIPES & WYES
PVC (SCH 40)ASTM D1785, D2665, F794
*OR OTHER FROM TABLE 701.2
8.2 AT CROSSINGS & WITHIN 10' OF BUILDING
ABS (SCH 40)ASTM D2661 & D2680
CAST-IRON ASTM A74, ASTM A888
PVC (SCH 40)ASTM D1785, D2665, F794
*OR OTHER FROM TABLE 701.2
8.3 ALL OTHER LOCATIONS
ABS (SCH 40)ASTM D2661 & D2680
CAST-IRON ASTM A74, ASTM A888
PVC (SCH 40)ASTM D1785, D2665, F794
PVC PSM ASTM D3034
* OR OTHER FROM TABLE 701.2
9.CONTRACTOR AND MANHOLE FABRICATOR SHALL SUMP (LOWER) ALL STORM SEWER CATCH BASIN CASTINGS WITHIN
PAVED AREAS 0.16 FEET OR 2-INCHES BELOW THE RIM ELEVATION DEPICTED ON THE UTILITY PLAN.
10.ALL STREET REPAIRS AND PATCHING SHALL BE PERFORMED PER THE REQUIREMENTS OF THE CITY. ALL TRAFFIC
CONTROL SHALL BE PROVIDED BY THE CONTRACTOR AND SHALL BE ESTABLISHED PER THE REQUIREMENTS OF THE
MINNESOTA MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MMUTCD) AND THE CITY. THIS SHALL INCLUDE ALL
SIGNAGE, BARRICADES, FLASHERS AND FLAGGERS AS NEEDED. ALL PUBLIC STREETS SHALL BE OPEN TO TRAFFIC AT ALL
TIMES. NO ROAD CLOSURES SHALL BE PERMITTED WITHOUT THE EXPRESSED AUTHORITY OF OF THE CITY.
11.PIPE LENGTHS SHOWN ON THE PLAN INCLUDE THE APRON SECTION.
12.TRENCH COMPACTION SHALL BE 95% STANDARD PROCTOR DENSITY IN THE AREA FROM THE PIPE ZONE TO WITHIN 3
FEET OF FINISHED GRADE AND 100% IN FINAL 3 FEET OF THE BACKFILL TO FINISH GRADE.
13.ALL INSULATION SHALL BE 3 INCH THICK RIGID AND WIDTH SHALL MATCH THE DETAIL ON C8-1. OVERLAP
SHEETS/BOARDS OF INSULATION TO ENSURE CONTINUOUS FROST PROTECTION.
14.SILVA CELL VENDOR/SUPPLIER TO PROVIDE SHOP SUBMITTAL THAT ENSURES COMPARABLE STORAGE AND ALL
NECESSARY ACCESS PORTALS FOR SYSTEM MAINTENANCE. CELLS SHALL BE VOID AND EMPTY FOR TEMP WATER
STORAGE WITH NO SOIL MEDIA WITHIN.
UTILITY NOTES
LOUCKS
W:\2026\260351\CADD DATA\CIVIL\_dwg Sheet Files\C8-1 CIVIL DETAILS12755 Highway 55, Suite R100
Plymouth, MN 55441
763.424.5505
www.loucksinc.com
PLANNING
CIVIL ENGINEERING
LAND SURVEYING
LANDSCAPE ARCHITECTURE
ENVIRONMENTAL
C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e
instruments of the Consultant professional services for use solely
with respect to this project. These CADD files shall not be used
on other projects, for additions to this project, or for completion
of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he
C onsultant . With t he Cons ultant's appr oval, ot hers may be
per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or
information and reference only. All intentional or unintentional
revisions, additions, or deletions to these CADD files shall be
made at the full risk of that party making such revisions, additions
or deletions and that party shall hold harmless and indemnify the
Consultant from any & all responsibilities, claims, and liabilities.
CADD QUALIFICATION
QUALITY CONTROL
PROFESSIONAL SIGNATURE
SUBMITTAL/REVISIONS
BLAZE
CREDIT UNION
CHANHASSEN
320 Lake Drive East
Chanhassen, MN 55317
2025 Larpenteur Ave. W.
Falcoln Heights, MN 55113
C1-1 DEMOLITION PLAN
C2-1 SITE PLAN
C3-1 GRADING PLAN
C3-2 SWPPP
C3-2 SWPPP NOTES
C4-1 SANITARY AND WATERMAIN PLAN
C4-2 STORM SEWER PLAN
C8-1 CIVIL DETAILS
C8-2 CIVIL DETAILS
L0-1 TREE REPLACEMENT PLAN
L1-1 LANDSCAPE PLAN
L2-1 LANDSCAPE DETAILS
10/02/26 ENTITLEMENTS SUBMITTAL
License No.
Date
I hereby certify that this plan, specification or report was
prepared by me or under my direct supervision and that
I am a duly Licensed Professional Engineer under the
laws of the State of Minnesota.
46607
10/02/26
Brian M. Johnson - PE
Review Date
Project Lead
Drawn By
Checked By
Loucks Project No.
10/02/26
BMJ
BMJ
BMJ
260351
CIVIL
CONSTRUCTION
DETAILS
C8-1
BIO-ROLL OR
ROCK LOG
NOTES:
1.PLACE BOTTOM EDGE OF WIRE FENCE INTO 6 IN DEEP TRENCH.
2.POSTS SHALL BE:
·6 FT MAX. SPACING.
·STANDARD STEEL T-TYPE POSTS.
·5' MIN. LENGTH POSTS, DRIVEN 2 FT INTO THE GROUND.
3.ATTACH WIRE FENCE TO STEEL POSTS WITH NO. 9 GA. ALUMINUM WIRE OR NO. 9
GALVANIZED STEEL PRE-FORMED CLIPS.
4.ATTACH FABRIC TO WIRE FENCING WITH WIRE OR ZIP TIES. A MIN. OF 3 ZIP TIES
PER POST. EXTEND BOTTOM OF FABRIC INTO TRENCH.
5.BACKFILL TRENCH & COMPACT.
6.STRAW, WOOD CHIP, COMPOST OR ROCK LOGS PER MNDOT SPECS 3890, 3897.
DRAWN 11/2016
LOUCKS PLATE NO.
3002
2'' X 2'' X 18'' LONG WOODEN
STAKES AT 2'-0'' SPACING. DRIVE
THROUGH NETTING, NOT
PENETRATING FIBER LOG.
STRAW OR WOOD FIBER 9"
OR 12'' DIA. SEDIMENT
LOG ROLL ENCLOSED IN
POLYPROPYLENE NETTING
FL
O
W
TRENCH IF LOOSE SOILS
FLOW
ENDS SECURELY CLOSED TO PREVENT
LOSS OF OPEN GRADED AGGREGATE
FILL. SECURED WITH 50 PSI. ZIP TIE
1
NOTES:
SEE SPECS. 2573, 3137, 3890 & 3897.
MANUFACTURED ALTERNATIVES LISTED ON Mn/DOT'S APPROVED
PRODUCTS LIST MAY BE SUBSTITUTED.
1.GEOTEXTILE SOCK BETWEEN 4-10 FEET LONG AND 4-6 INCH
DIAMETER. SEAM TO BE JOINED BY TWO ROWS OF STITCHING
WITH A PLASTIC MESH BACKING OR PROVIDE A HEAT BONDED
SEAM (OR APPROVED EQUIVALENT). FILL ROCK LOG WITH
OPEN GRADED AGGREGATE CONSISTING OF SOUND
DURABLE PARTICLES OF COARSE AGGREGATE CONFORMING
TO SPEC. 3137 TABLE 3137-1; CA-3 GRADATION.
SILT FENCE
FLOW
6"
6"
NOTES:
1.PLACE BOTTOM EDGE OF FENCE INTO 6 IN DEEP TRENCH
AND BACKFILL IMMEDIATELY.
2.POSTS SHALL BE:
·6 FT MAX. SPACING.
·2 IN X 2IN HARDWOOD, OR STANDARD STEEL T-TYPE
FENCE POSTS.
·5' MIN. LENGTH POSTS, DRIVEN 2 FT INTO THE
GROUND.
3.ATTACH FABRIC TO WOOD POST WITH A MIN. OF 5, 1
INCH LONG STAPLES.
4.ATTACH FABRIC TO STEEL POST WITH A MIN. OF 3 ZIP
TIES IN TOP 8 INCHES OF FABRIC.
GEOTEXTILE FABRIC
PER MNDOT 3886
GEOTEXTILE
FABRIC PER
MNDOT 3886
DRAWN 2/2016
LOUCKS PLATE NO.
3000
HARD SURFACE PUBLIC ROAD
2' MINIMUM
1" TO 2" WASHED ROCK
50
'
M
I
N
I
M
U
M
AS R
E
Q
UI
R
E
D4:1
4:1
6" MINIMUM
ROCK ENTRANCE TO
CONSTRUCTION SITE
NOTES:
1.ROCK SIZE SHOULD BE 1" TO 2" IN SIZE SUCH AS MN/DOT CA-1 OR
CA-2 COURSE AGGREGATE. (WASHED)
2.A GEOTEXTILE FABRIC MAY BE USED UNDER THE ROCK TO PREVENT
MIGRATION OF THE UNDERLYING SOIL INTO THE STONE.
DRAWN 2/2016
LOUCKS PLATE NO.
3004 EROSION CONTROL BLANKET
6"
6"
1' TO 3'ANCHOR TRENCH
1.DIG 6"X6" TRENCH
2.LAY BLANKETS IN TRENCH
3.STAPLE AT 1.5' INTERVALS
4.BACKFILL WITH NATURAL SOIL
AND COMPACT.
5.BLANKET LENGTH SHALL NOT
EXCEED 100' WITHOUT AN
ANCHOR TRENCH
NOTE:
SLOPE SURFACE SHALL BE FREE OF ROCKS, SOIL
CLUMPS, STICKS, VEHICLE IMPRINTS, AND GRASS.
BLANKETS SHALL HAVE GOOD SOIL CONTACT.
ANCHOR TRENCH
(SEE DETAIL AND NOTES BELOW)
OVERLAP END JOINTS MINIMUM
OF 6" AND STAPLE OVERLAP AT
1.5' INTERVALS.
OVERLAP LONGITUDINAL
JOINTS MINIMUM OF 6"
STAPLE PATTERN/DENSITY
SHALL FOLLOW
MANUFACTURERS
SPECIFICATIONS.
DI
R
E
C
T
I
O
N
O
F
SU
R
F
A
C
E
F
L
O
W
STAGGER JOINTS
DRAWN 2/2016
LOUCKS PLATE NO.
3016
NOTES:
6" HUB WITH THREADED PVC PLUG - DO NOT GLUE
CASTING MAY BE REQUIRED SEE SPECIFICATIONS
END OF LINE CLEANOUT IN LINE CLEANOUT
PVC LONG SWEEP
BEND SCH. 40
ONE PIECE 6" PVC
SCH. 40 CLEANOUT
RISER
DRAINTILE
CLEAN-OUT STRUCTURE
DRAWN 2/2016
LOUCKS PLATE NO.
4315
SEE PLAN FOR SIZE
OF DRAINTILENOTES:
1.SCHEDULE 40 PVC TO BE USED FOR ALL STORM SEWER PIPE RUNS FROM ROOF DRAINS.
2.A WATER-TIGHT CONNECTION SHALL BE MAINTAINED WITH ANY TRANSITION FROM SCHEDULE 40
PVC PIPE TO ANY OTHER PIPE TYPE.
3.THE DOWNSPOUT COLLECTOR DRAIN SHALL BE INSTALLED BEFORE THE DOWNSPOUTS ARE
INSTALLED ON THE BUILDING. SITE WORK CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK TO,
AND INCLUDING, THE RODENT SCREEN. BUILDING CONTRACTOR SHALL BE RESPONSIBLE FOR THE
CONNECTION AT TEH POINT OF THE RODENT SCREEN.
LOUCKS PLATE NO.
DOWNSPOUT
CONNECTION
"HYDRANTFINDER" SHALL BE INSTALLED ON THE TOP OF THE
UPPER FLANGE ON THE REAR BOLTS. INSTALL PLASTIC
COMPOSITE HYDRANTFINDERS ONLY. EXPOSED FIBERGLASS AND
METAL
HYDRANTFINDERS SHALL NOT BE USED.
INSTALL ADAPTOR
INC.'S VALVE BOX
ADAPTOR #6 BASE OR
APPROVED EQUAL
6" AMERICAN FLOW
CONTROL 2500 SERIES
RESILIENT WEDGE TYPE
GATE VALVE OR APPROVED
EQUAL.
HYDRANT AND GATE
VALVE INSTALLATION
NOTES:
1.GATE VALVES ARE REQUIRED WITH ALL HYDRANTS.
2.THRUST BLOCKING REQUIRED BEHIND ALL HYDRANTS.
3.ALL BOLTS, T-BOLTS, NUTS AND RODDING INSTALLED BELOW GRADE SHALL BE
ASTM F593 TYPE 316 STAINLESS STEEL. THIS INCLUDES HYDRANTS AND VALVES.
CONCRETE
BLOCKCONCRETEBLOCK MEGALUG
UNDISTURBED SOIL CONCRETE
BLOCK
7.5' MIN. COVER
ON WATERMAIN
MEGALUG
1 CUBIC YARD GRAVEL OR
CRUSHED ROCK WITH 2
LAYERS OF 4 MIL POLY. (2/3 OF
MATERIAL BELOW HYDRANT)2.5'16"TRAFFICFLANGE2-1/2" HOSE CONNECTION
(NATIONAL STANDARD THREAD)
CAPS TO BE CHAINED
(PENTAGON NUT ON CAPS)
4-1/2" PUMPER CONNECTION
(NATIONAL STANDARD THREAD)
NATIONAL STANDARD OPERATING NUT
3'-0"2'-0"
FINISHED BOULEVARD GRADE
SEE STANDARD
PLATE 4601 FOR
APPROVED TYPES OF
GATE VALVE BOXES
DRAWN 12/2016
LOUCKS PLATE NO.
4600
NOTE:
GRANULAR MATERIALS FURNISHED FOR USE IN FOUNDATION, BEDDING, ENCASEMENT, OR BACKFILL
CONSTRUCTION SHALL CONFORM TO THE FOLLOWING REQUIREMENTS:
·FOUNDATION MATERIALS SHALL HAVE 100% PASSING THE 1 1/2" SIEVE AND A MAXIMUM OF 10%
PASSING THE No. 4 SIEVE. NOT LESS THAN 50% OF THE MATERIAL RETAINED BY THE No. 4 SIEVE SHALL
HAVE ONE (1) OR MORE CRUSHED FACES. HARD, DURABLE CRUSHED CARBONATE QUARRY ROCK MAY
BE USED FOR FOUNDATION MATERIALS.
·BEDDING AND ENCASEMENT MATERIALS FOR FLEXIBLE PIPE SHALL MEET THE REQUIREMENTS OF
MNDOT SPECIFICATION 3149.2B1, GRANULAR BORROW, EXCEPT THAT 100% SHALL PASS THE ONE
INCH (1") SIEVE.
·BACKFILL MATERIALS SHALL CONSIST OF SUITABLE EXISTING TRENCH MATERIALS, EXCEPT AS
OTHERWISE SPECIFIED. SUITABLE MATERIAL SHALL BE DEFINED AS A MINERAL SOIL FREE OF FOREIGN
MATERIALS (RUBBISH, ORGANICS & DEBRIS), FROZEN CLUMPS, OVERSIZE STONE, ROCK, CONCRETE
OR BITUMINOUS CHUNKS, AND OTHER UNSUITABLE MATERIALS THAT MAY DAMAGE PIPE, PREVENT
THOROUGH COMPACTION, OR INCREASE THE RISKS OF SETTLEMENT.
PLASTIC PIPE
BEDDING
PLASTIC
PIPE
18"18"PIPE
WIDTH ENCASEMENT
BEDDING
FOUNDATION
(MAY NOT BE
REQUIRED)
12"
6"
BACKFILL
COMPACTED
AS SPECIFIED
EXCAVATED TRENCH
WIDTH
DRAWN 2/2016
LOUCKS PLATE NO.
4008
GATE VALVES
FINISHED GRADE
7.5' MINIMUM COVERVARIABLEVAR.MIDDLE SECTION
EXTENSIONS
TOP SECTION
VARIABLE14-3/4
17-1/412-9/167
8-1/4
9-7/16
7-3/4
78-1/8
2-3/8
7
8-1/8 61-1/2
5-3/4
5-1/4
6-5/8
7-1/8
7-5/8
8-7/8
2"
6-1/4 WATER
7-3/8
2"
4"
5-3/4
7-1/8
NOTE: ALL BOLTS, T-BOLTS, NUTS AND RODDING
INSTALLED BELOW GRADE SHALL BE ASTM F593
TYPE 316 STAINLESS STEEL.
AMERICAN FLOW CONTROL 2500 SERIES
RESILIENT WEDGE TYPE OR APPROVED
EQUAL. VALVE BODY BOLTS SHALL BE
ASTM F593 TYPE 316 STAINLESS STEEL.
INSTALL ADAPTOR INC.'S VALVE
BOX ADAPTOR #6 BASE OR
APPROVED EQUAL
ADJUST V.B. TOP TO 14" TO 12" BELOW
STREET GRADE OR 12" TO 1" BELOW
FINISHED BLVD. GRADE AND SHALL BE
SET SO AS TO PROVIDE 12" OF
UPWARD ADJUSTMENT.
GATE VALVE BOXES:
TYLER PIPE - SERIES 6860 SCREW TYPE
WITH A #6 BASE AND DROP LIDS
WITH "WATER" LABELED ON COVER
OR APPROVED EQUAL OFF ROAD MARKERG
V
GATE VALVE AND
BOX INSTALLATION
NO. 6 ROUND BASE
CONCRETE
BLOCK
GATE VALVE BOXES ARE
3 PIECE, 5-1/4" SHAFT
14" MIN. FROM TOP OF BOTTOM
SECTION TO TOP OF VALVE BOX
DRAWN 2/2016
LOUCKS PLATE NO.
4601
LOOP TRACER WIRE
AROUND WYE
CONTINUOUS #10 SOLID
COPPER, INSULATED TRACER
WIRE FROM WYE DIRECTLY
ABOVE THE SVC PIPE, TO TOP
OF FENCE POST
TRACER WIRE FOR
NON-CONDUCTIVE
SEWER PIPE
4" D.I.P. OR P.V.C.
BENDS, 1/8 OR
1/16
PLUG WYEPROPERTYLINE FLOWNOTES:
1.SPLICING TRACER WIRE SHALL BE BY MECHANICAL
SPLIT BOLT TYPE OR A CRIMP TYPE COMPRESSION
FITTING, FULLY ENCASED IN APPROVED
ELECTRICAL INSULATION PUTTY.
2.WIRE SHALL BE SECURED TO PIPE WITH 2" WIDE
PVC TAPE. SECURE WIRE AT ALL BENDS, WYES &
LONGITUDINALLY EVERY 10 FEET.
DRAWN 2/2016
LOUCKS PLATE NO.
4007
LOUCKS
W:\2026\260351\CADD DATA\CIVIL\_dwg Sheet Files\C8-1 CIVIL DETAILS12755 Highway 55, Suite R100
Plymouth, MN 55441
763.424.5505
www.loucksinc.com
PLANNING
CIVIL ENGINEERING
LAND SURVEYING
LANDSCAPE ARCHITECTURE
ENVIRONMENTAL
C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e
instruments of the Consultant professional services for use solely
with respect to this project. These CADD files shall not be used
on other projects, for additions to this project, or for completion
of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he
C onsultant . With t he Cons ultant's appr oval, ot hers may be
per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or
information and reference only. All intentional or unintentional
revisions, additions, or deletions to these CADD files shall be
made at the full risk of that party making such revisions, additions
or deletions and that party shall hold harmless and indemnify the
Consultant from any & all responsibilities, claims, and liabilities.
CADD QUALIFICATION
QUALITY CONTROL
PROFESSIONAL SIGNATURE
SUBMITTAL/REVISIONS
BLAZE
CREDIT UNION
CHANHASSEN
320 Lake Drive East
Chanhassen, MN 55317
2025 Larpenteur Ave. W.
Falcoln Heights, MN 55113
C1-1 DEMOLITION PLAN
C2-1 SITE PLAN
C3-1 GRADING PLAN
C3-2 SWPPP
C3-2 SWPPP NOTES
C4-1 SANITARY AND WATERMAIN PLAN
C4-2 STORM SEWER PLAN
C8-1 CIVIL DETAILS
C8-2 CIVIL DETAILS
L0-1 TREE REPLACEMENT PLAN
L1-1 LANDSCAPE PLAN
L2-1 LANDSCAPE DETAILS
10/02/26 ENTITLEMENTS SUBMITTAL
License No.
Date
I hereby certify that this plan, specification or report was
prepared by me or under my direct supervision and that
I am a duly Licensed Professional Engineer under the
laws of the State of Minnesota.
46607
10/02/26
Brian M. Johnson - PE
Review Date
Project Lead
Drawn By
Checked By
Loucks Project No.
10/02/26
BMJ
BMJ
BMJ
260351
CIVIL
CONSTRUCTION
DETAILS
C8-2
FLAT CURB AND
GUTTER (12")
DRAWN 2/2016
LOUCKS PLATE NO.
2012
SLOPE GUTTER TO MATCH
PARKING LOT DRAINAGE
TIP GUTTER OUT AS REQ'D
PAVEMENT SECTION VARIES
MIN. OF 4"
3/8 " LIP
AGG. BASE UNDER
CURB (IF TOTAL
THICKNESS OF
SECTION ALLOWS)
7"
12"8"
AGG. BASE
VARIES
1/2" RAD.
20"
SPECIFICATION NOTES:
1.UPON COMPLETION, CURBING SHOULD BE SPRAYED WITH A
MEMBRANE CURING COMPOUND PER MNDOT 3754.
2.EXPANSION JOINTS AT MAX. SPACING OF 200'.
3.CONSTRUCT IN ACCORDANCE WITH MNDOT 2531.
CONCRETE SIDEWALK-
WIDTH & SECTION VARY
REFER TO SITE PLAN
6" COMPACTED AGGREGATE BASE CL. 5 OR 2
MN/DOT 3138
APPROVED SUBGRADE
FINISHED GRADE
5" CONCRETE MN/DOT 2301
CONCRETE PAVEMENT
SECTION
NOTES:
1.CONCRETE 6" THICK OR LESS SHALL BE REINFORCED WITH WELDED WIRE
FABRIC OR REINFORCING BARS. CONCRETE 7" THICK OR GREATER SHALL
BE REINFORCED PER GEOTECHNICAL RECOMMENDATIONS.
2.SAWED OR FORMED CONTROL JOINTS SHOULD BE INCLUDED FOR EACH
225 SQUARE FEET OF AREA OR LESS (15 FEET BY 15 FEET).
3.PANEL DIMENSION RATIO SHALL NOT EXCEED 1.25:1.
4.ALL JOINTS SHALL BE A MINIMUM OF 1
4 THE THICKNESS OF CONCRETE.
5.SAW CUTS SHOULD NOT CUT THROUGH THE WELDED WIRE FABRIC OR
REINFORCING STEEL AND DOWELS SHOULD BE UTILIZED AT FORMED
AND/OR COLD JOINTS.
DRAWN 12/2016
LOUCKS PLATE NO.
2033
PAVEMENT SECTION BASED ON
GEOTECHNICAL REPORT BY BRAUN
INTERTEC, DATED ****pending****
CONCRETE SIDEWALK
4" CONCRETE WALK
MN/DOT SPEC. 2521
4" GRANULAR MATERIAL
MN/DOT SPEC. 3149
CONCRETE SIDEWALK
DRAWN 12/2016
LOUCKS PLATE NO.
2035
1'-0"ACCESSIBLE ROUTE
LSEE PLAN8'-0"8'-0"8'-0"9'-0"
C
18'-0"C
TYPICAL ADA PARKING
4" WIDE PAINTED
LINES, TRAFFIC
WHITE
4" WIDE PAINTED LINES,
18" O.C., @ 45 TRAFFIC
WHITE
(AISLE TO CONTAIN THE
DESIGNATION "NO
PARKING" COMPLYING
WITH MSBC 1341.0502)
ACCESSIBLE SIGN (TYP)
(SIGN TO COMPLY WITH MINNESOTA
RULES 1341.0502
DRAWN 12/2016
LOUCKS PLATE NO.
2036
TC=0
GL=-0.5
TC=0
GL=0
TC=0
GL=0
TC=0
GL=-0.51'-0"ACCESSIBLE ROUTE
SEE PLANACCESSIBLE SIGN/BOLLARD (TYP)
(SIGN TO COMPLY WITH MINNESOTA RULES
1341.0502
TC=0
GL=0
TC=0
GL=0
TC=0
GL=0
TC=0
GL=0
B612 CURB
& GUTTER
FLAT CURB
TC=0
GL=-0.5
TC=0
GL=-0.5
TC=0
GL=-0.5
FLAT CURB
B612 CURB
& GUTTER
B612 CURB
& GUTTER
FULL HEIGHT CURB WITH FLAT CURB AT ACCESS AISLE
FULL HEIGHT CURB ENTIRE WIDTH OF ADA STALLS
VAN
ACCESSIBLE
60" - 66"48"12" DIA.36"TYPICAL ADA PARKING
SIGN / BOLLARD COMBO
12x18" STANDARD ACCESSIBLE PARKING
SIGN WITH SEPARATE 'VAN ACCESSIBLE'
PANEL. WHITE LEGEND ON BLUE
BACKGROUND. USE HARDWARE PER
SIGN SUPPLIER'S RECOMMENDATIONS.
ADA SIGNAGE PER MINNESOTA
RULES 1341.0502
12x6" STANDARD 'VAN
ACCESSIBLE' PANEL. WHITE
LEGEND ON BLUE BACKGROUND
2" DIA. 6' LONG MIN.
GALVANIZED SCHEDULE 40
STEEL PIPE. EMBED IN
CONCRETE FILLED BOLLARD
6" DIA. SCHEDULE 40
GALVENZIED STEEL PIPE 6'
LONG MINIMUM
HEAVY DUTY HDPE DOME TOP
DECORATIVE SLEEVE BLUE IN COLOR.
AVAILABLE FROM
BOLLARDSNSLEEVES.COM OR EQUAL.
COMPACTED OR
UNDISTURBED SUBGRADE.
NOTES:
1.BOLLARDS TO BE PLACED 12" BEHIND
BACK OF CURB.
2.MAINTAIN PLUMB UNTIL CONCRETE IS
SUFFICIENTLY CURED.
3.HOLD CONCRETE FOOTING BELOW
GRADE OF FINISHED CONCRETE TO
CREATE FINAL PAVING PATTERN AS
SHOWN ON PLANS.
DRAWN 12/2016
LOUCKS PLATE NO.
20386"PARKING
VEHICLE ID
REQUIRED
UP TO $200 FINE
FOR VIOLATION
BOLLARD
1/2" CROWN
1" CROWN
3'-6"3'-0"6"24" DIA.
4,000 PSI
CONCRETE
6" DIP, CONC.
FILLED, PAINTED
OSHA YELLOW
DRAWN 12/2016
LOUCKS PLATE NO.
2039
2" BIT. WEAR COURSE,
MN/DOT 2360 SPWEA340C
TACK COAT, MN/DOT 2357
2" BIT. NON-WEAR COURSE,
MN/DOT 2360 SPNWB330C
10" AGG. BASE, CLASS 5 OR 2 MN/DOT 3138
APPROVED SUBGRADE
FINISHED GRADE
STANDARD BITUMINOUS
PAVEMENT SECTION
PAVEMENT SECTION BASED ON
GEOTECHNICAL REPORT BY BRAUN
INTERTEC, DATED ****pending****
DRAWN 12/2016
LOUCKS PLATE NO.
2031
STANDARD GUTTER
8"12"
6"
13.5"
1
2" RAD.
MIN. OF 4" AGG. BASE
UNDER CURB (IF TOTAL
THICKNESS OF
SECTION ALLOWS)
3/8 " LIP
3" RAD.
1
3
3" RAD.
AGG. BASE
VARIES
SLOPE GUTTER TO
MATCH PARKING LOT
DRAINAGE
(3/4" PER FT. TYP.) TIP
GUTTER OUT AS REQ'D
B612 STYLE
CONCRETE CURB
AND GUTTER
MINIMUM 1'
BEHIND BACK
OF CURB
7"
SPECIFICATION NOTES:
1.UPON COMPLETION, CURBING SHOULD BE SPRAYED WITH A
MEMBRANE CURING COMPOUND PER MNDOT 3754.
2.EXPANSION JOINTS AT MAX. SPACING OF 200'.
3.CONSTRUCT IN ACCORDANCE WITH MNDOT 2531.
DRAWN 2/2016
LOUCKS PLATE NO.
2009
TRAFFIC SIGN
3#/FT.
3#/FT.
TRAFFIC SIGN SPECIFICATIONS
STOP SIGN SHALL BE R1-1, 30"X30" OR AS
DIRECTED BY ENGINEER.
MATERIAL
ALUMINUM SHALL BE 5052-H38 OR 6061-T6
ALLOY.
GAUGE SHALL BE 0.080 ON THE LONGEST
SIDE UP TO 30", 0.100 ON THE LONGEST SIDE
OVER 30".
REFLECTIVE SHEETING SHALL BE DIAMOND
GRADE VIP.
ALL SIGNS SHALL CONFORM TO MN/DOT
3352, SIGNS, DELINEATORS AND MARKERS -
STANDARD SPECIFICATIONS FOR
CONSTRUCTION.
CHANNEL POST SPECIFICATIONS
STEEL CHANNEL POSTS SHALL WEIGH 3LB.
/FT.
POSTS SHALL BE OF THE 4-RIB DESIGN,
GALVANIZED AND PUNCHED ON 1" CENTERS.3'-0"7'-0"IF INSTALLED IN PAVEMENT, INSTALL
V-LOC ANCHOR OR APPROVED EQUAL.
DRAWN 12/2016
LOUCKS PLATE NO.
2041
VINYL PRIVACY FENCE
SCALE: NA filename.dwg42"8' TYP
12" DIAM6'-0"EXISTING SUBGRADE
VINYL PRIVACY FENCE
HEIGHT: 6 FEET
COLOR: WHITE
CONCRETE FOOTING
TOPSOIL FOR GROUND COVER
-
1/2" Per Ft.
18"18"
3"3 1/2"7"36" CONCRETE VALLEY
GUTTER
4" MIN. AGGREGATE BASE
No. 4 REBAR (TYP)
DRAWN 2/2016
LOUCKS PLATE NO.
2018
LOUCKS
W:\2026\260351\CADD DATA\CIVIL\_dwg Sheet Files\C8-1 CIVIL DETAILS12755 Highway 55, Suite R100
Plymouth, MN 55441
763.424.5505
www.loucksinc.com
PLANNING
CIVIL ENGINEERING
LAND SURVEYING
LANDSCAPE ARCHITECTURE
ENVIRONMENTAL
C ADD f iles pr epar ed by t he Cons ult ant for this p roject ar e
instruments of the Consultant professional services for use solely
with respect to this project. These CADD files shall not be used
on other projects, for additions to this project, or for completion
of t his p r ojec t by ot her s w it hou t wr i t te n ap pr ov al b y t he
C onsultant . With t he Cons ultant's appr oval, ot hers may be
per mit t ed t o ob t ain cop ies of t he C AD D dr aw ing files f or
information and reference only. All intentional or unintentional
revisions, additions, or deletions to these CADD files shall be
made at the full risk of that party making such revisions, additions
or deletions and that party shall hold harmless and indemnify the
Consultant from any & all responsibilities, claims, and liabilities.
CADD QUALIFICATION
QUALITY CONTROL
PROFESSIONAL SIGNATURE
SUBMITTAL/REVISIONS
BLAZE
CREDIT UNION
CHANHASSEN
320 Lake Drive East
Chanhassen, MN 55317
2025 Larpenteur Ave. W.
Falcoln Heights, MN 55113
C1-1 DEMOLITION PLAN
C2-1 SITE PLAN
C3-1 GRADING PLAN
C3-2 SWPPP
C3-2 SWPPP NOTES
C4-1 SANITARY AND WATERMAIN PLAN
C4-2 STORM SEWER PLAN
C8-1 CIVIL DETAILS
C8-2 CIVIL DETAILS
L0-1 TREE REPLACEMENT PLAN
L1-1 LANDSCAPE PLAN
L2-1 LANDSCAPE DETAILS
10/02/26 ENTITLEMENTS SUBMITTAL
License No.
Date
I hereby certify that this plan, specification or report was
prepared by me or under my direct supervision and that
I am a duly Licensed Professional Engineer under the
laws of the State of Minnesota.
46607
10/02/26
Brian M. Johnson - PE
Review Date
Project Lead
Drawn By
Checked By
Loucks Project No.
10/02/26
BMJ
BMJ
BMJ
260351
CIVIL
CONSTRUCTION
DETAILS
C8-3
UNDERGROUND FILTRATION SYSTEM SECTION
SCALE: N/A
TBD
TBD
TBD
TBD
84" HDPE PIPE 84" HDPE PIPE 84" HDPE PIPE
FREE DRAINING ANGULAR WASHED STONE NON
LIMESTONE/CARBONATE MATERIAL 3/8" MIN.
PARTICLE SIZE. THE MAXIMUM LOS ANGELES RATTLER
LOSS SHOULD BE 35% PER AASHTO T-96 AND NO
GREATER LOSS THAN 10% PER AASHTO T-104
MAGNESIUM SULFATE SOUNDNESS TEST ON THE
NON-IGNEOUS PORTIONS AND AS MODIFIED BY THE
MNDOT LABORATORY MANUAL (MNDOT 2005)
COMPACT TO MIN. 90% STANDARD DENSITY PER
AASHTO T-99 PLACED IN LIFTS OF 4-6"
INSTALL CMP PIPE PER ASSHTO M-36,
AASHTO SECTION 12 OR HDPE PER
ASTM D2321
NON-WOVEN GEOTEXTILE FABRIC
AROUND SIDES & BOTTOM OF TRENCH
& PIPE. DO NOT PLACE NON-WOVEN
FABRIC ON TOP OF TRENCH.
GRANULAR BEDDING, ROUGHLY
SHAPED TO FIT THE BOTTOM OF PIPE,
6" IN DEPTH.
(2) 6" SLOTTED SINGLE WALL HDPE DRAINTILE
W/ CIRCULAR KNOT POLYMERIC FILAMENT
FILTER SOCK PER ASTM D6707-10. MNDOT 3733
TYPE 1 SEWN SEAM NON-WOVEN FABRIC
SHALL NOT BE USED.
24" LAYERED MEDIA SECTION
TOP 6" - MEDIA MIX C
MIDDLE 8" - ASTM 33 SAND
BOTTOM 10" - ASTM 33 SAND WITH 5%
IRON FILLING BY VOLUME
WOVEN GEOTEXTILE FABRIC ON TOP OF
TRENCH.
IRON ENHANCED FILTRATION TANK
VOLUME: 1" OVER IRRIGATION AREA (2x)
VOLUME: WATER QUALITY
WATER QUALITY VOLUME
MECHANICAL ELEVATION CONTROL
940.02
BACKFLOW
PREVENTOR
FILTERED WATER TO RE-USE TANK
FLOW IN EXCESS OF
WQV BYPASS TO OFFSITE
3' SUMP & SNOUT
FOR PRETREATMENT
2-YEAR, HWL=941.27
10-YEAR, HWL=941.73
100-YEAR, HWL=942.93
IRRIGATION REUSE
MECHANICAL ELEVATION CONTROL
939.75
STMH#101 STMH#104
CBMH#106
WITH HYDROSTATIC (HEAD) PRESSURE
EXCESS VOLUME GREATER THAN THE
IRRIGATION VOLUME THAT MAY BE
FILTERED HAS A PATH TO DISCHARGE SITE
STORMWATER MANAGEMENT SYSTEM SECTION
SCALE: N/A
EXISTING PIPE
PROJECT OUTFALL
930.70
936.70
943.70
939.75
940.02
IRRIGATION / RE-USE TANK
VOLUME (FULL)=594 CF
VOLUME (THIS TANK)=2,818 CF
VOLUME (THIS TANK)=3,147 CF
IRRIGATION VOLUME PROVIDED
REUSE TANK VOLUME =594 CF
FILTRATION TANK VOLUME =2,818 CF
TOTAL =3,412 CF
WATER QUALITY VOLUME PROVIDED
REUSE TANK VOLUME =594 CF
FILTRATION TANK VOLUME =3,147 CF
TOTAL =3,741 CF (> 3,735 CF REQ'D)1'-4"VARIABLE6"3"6"4.0'
OUTLET FLOW 3'MIN.2"
0"-8"
2"
NYLOPLAST SNOUT STRUCTURE
OR APPROVED EQUAL.
CONCRETE
ADJUSTING RINGS,
MIN. 4" - MAX. 10"
NOTE:
24"x36" SLAB OPENING FOR NEENAH R-3067 CASTING WITH D.L., D.R. OR TYPE V GRATE.
27" ɸ SLAB OPENING FOR NEENAH R-3250 & R-1733 CASTING.
SUMP CATCH BASIN /
MANHOLE
MINIMUM SLAB THICKNESS IS 6" FOR 14'
DEPTH. INCREASE THICKNESS 1" FOR 4'
OF DEPTH GREATER THAN 14'.
PRECAST CONCRETE MANHOLE
SECTIONS WITH "O"-RING RUBBER
GASKETS.
SLAB TOP TO BE SET IN
A MORTAR BED.
6" PRECAST
REINFORCED
CONCRETE SLAB.
STEPS 16" O.C. ON DOWNSTREAM
SIDE.
EXTRUDED ALUMINUM OR STEEL
REINFORCED COPOLYMER PLASTIC.6"DRAWN 2/2016
LOUCKS PLATE NO.
4304LOUCKS
NO PARKING
PROPOSED
CREDIT UNION
5,050 SF
FFE-949.25DO NOT ENTER947
948
949
9
4
8948949
94894
8
948
950
949
950
951
952
950 949947948 950
947
9
4
8
949
4
44448888888
8
95095095094894995195288888 8 88
88888888
8
8
85
HE-D
5
CO-F
3
HE-D
3
HE-D
3
HY-I
3
TA-T
4
HY-I
6
HE-D
6
CA-K
5
JU-G
6
CA-K
7
HE-B
10
JU-Z
4
HE-B
4
CA-K
5
JU-G
3
HE-D
6
CA-K
4
HE-D
5
HE-D
1
MA-S
1
CE-O
1
CE-O
3
PI-S
2
AC-F
3
CE-O
3
AC-S
2
AC-S
10
SP-L
6
CA-K
1
TI-A
1
TI-A
17
CO-F
1
AC-F
3
HO-F
2
VI-T
RETAINING WALL (SEE GRADING PLAN)
EDGER-TYP
EDGER-TYP
MONUMENT SIGN
(SEE ARCH)
SYMBOL CODE QTY COMMON / BOTANICAL NAME CONT SIZE
ORNAMENTAL TREES
MA-S 1 SPRING SNOW CRABAPPLE / MALUS X `SPRING SNOW`B&B 1.5" CAL
1 SUBTOTAL:
DECIDUOUS TREES
AC-F 3 ARMSTRONG MAPLE / ACER FREEMANII `ARMSTRONG`B&B 2.5" CAL
AC-S 5 SIENNA GLEN MAPLE / ACER FREEMANII `SIENNA GLEN`B&B 2.5" CAL
CE-O 5 COMMON HACKBERRY / CELTIS OCCIDENTALIS B&B 2.5" CAL
TI-A 2 BOULEVARD LINDEN / TILIA AMERICANA `BOULEVARD`B&B 2.5" CAL
15 SUBTOTAL:
EVERGREEN TREES
PI-S 3 SCOTCH PINE / PINUS SYLVESTRIS
FULL FORM B&B 6' HGT
3 SUBTOTAL:
SHRUBS
CO-F 22 ARCTIC FIRE DOGWOOD / CORNUS SERICEA `ARTIC FIRE`CONT 3' HGT
HY-I 7 INCREDIBALL HYDRANGEA / HYDRANGEA ARBORESCENS `INCREDIBALL`CONT 2' HGT
SP-L 10 LITTLE PRINCESS SPIREA / SPIREA JAPONICA `LITTLE PRINCESS`CONT
VI-T 2 COMPACT AMERICAN VIBURNUM / VIBURNUM TRILOBUM `BAILEY COMPACT`CONT 3' HGT
41 SUBTOTAL:
CONIFEROUS SHRUBS
JU-G 10 SEA GREEN JUNIPER / JUNIPERUS CHINENSIS `SEA GREEN`CONT #3
JU-Z 10 ARCADIA JUNIPER / JUNIPERUS SABINA `ARCADIA`CONT #3
TA-T 3 TAUNTON YEW / TAXUS X MEDIA `TAUNTON`CONT #3
23 SUBTOTAL:
PERENNIALS
HE-B 11 BAJA DAYLILY / HEMEROCALLIS X `BAJA`CONT
HE-D 29 STELLA D` ORO DAYLILY / HEMEROCALLIS X `STELLA DE ORO`CONT
HO-F 3 FRANCEE HOSTA / HOSTA `FRANCEE`CONT
43 SUBTOTAL:
GRASSES
CA-K 28 FEATHER REED GRASS / CALAMAGROSTIS X ACUTIFLORA `KARL FOERSTER`CONT 3' HGT
28 SUBTOTAL:
SYMBOL CODE QTY COMMON / BOTANICAL NAME
GROUND COVERS
HM-1 2,435 SF HARDWOOD MULCH
RM-1 323 SF ROCK MULCH
TS-1 17,355 SF TURF SOD
20,113 SF SUBTOTAL:
PLANT SCHEDULE
LOUCKS
W:\2026\260351\CADD DATA\LANDSCAPE\_dwg Sheet Files\L1-1 LANDSCAPE PLAN12755 Highway 55, Suite R100
Plymouth, MN 55441
763.424.5505
www.loucksinc.com
PLANNING
CIVIL ENGINEERING
LAND SURVEYING
LANDSCAPE ARCHITECTURE
ENVIRONMENTAL
CA DD f il es pr epar ed by t he Co ns ul tan t f or th is pr oje ct ar e
instruments of the Consultant professional services for use solely
with respect to this project. These CADD files shall not be used
on other projects, for additions to this project, or for completion
o f t h i s p r o j e ct b y o t h e r s w i t h o u t w r i t t e n a pp r o va l by t h e
Con su lt ant . W it h the C onsul ta nt 's appr ova l, othe rs ma y be
p e r m i t ted to ob tain co p ies o f t h e C AD D d r a win g f i l e s f o r
inf ormation and reference only. All intentional or unintentional
revisions, additions, or deletions to these CADD f iles shall be
made at the full risk of that party making such revisions, additions
or deletions and that party shall hold harmless and indemnify the
Consultant from any & all responsibilities, claims, and liabilities.
CADD QUALIFICATION
QUALITY CONTROL
PROFESSIONAL SIGNATURE
SUBMITTAL/REVISIONS
BLAZE
CREDIT UNION
CHANHASSEN
320 Lake Drive East
Chanhassen, MN 55317
2025 Larpenteur Ave. W.
Falcoln Heights, MN 55113
C1-1 DEMOLITION PLAN
C2-1 SITE PLAN
C3-1 GRADING PLAN
C3-2 SWPPP
C3-2 SWPPP NOTES
C4-1 SANITARY AND WATERMAIN PLAN
C4-2 STORM SEWER PLAN
C8-1 CIVIL DETAILS
C8-2 CIVIL DETAILS
L0-1 TREE REPLACEMENT PLAN
L1-1 LANDSCAPE PLAN
L2-1 LANDSCAPE DETAILS
10/02/26 ENTITLEMENTS SUBMITTAL
SHEET INDEX
Douglas D. Loken - LA
Review Date
SHEET INDEX
License No.
Date
I hereby certify that this plan, specification or report was
prepared by me or under my direct supervision and that
I am a duly Licensed Landscape Architect under the laws
of the State of Minnesota.
45591
Project Lead
Drawn By
Checked By
Loucks Project No.260351
BMJ
DDL
DDL
10/02/26
-
LANDSCAPE
PLAN
L1-1
CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMITTING BID. HE SHALL INSPECT SITE AND BECOME
FAMILIAR WITH EXISTING CONDITIONS RELATING TO THE NATURE AND SCOPE OF WORK.
VERIFY LAYOUT AND ANY DIMENSIONS SHOWN AND BRING TO THE ATTENTION OF THE LANDSCAPE
ARCHITECT ANY DISCREPANCIES WHICH MAY COMPROMISE THE DESIGN AND / OR INTENT OF THE
PROJECT'S LAYOUT.
ASSURE COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS GOVERNING THE WORK OR
MATERIALS SUPPLIED.
CONTRACTOR SHALL PROTECT ALL EXISTING ROADS, CURBS / GUTTERS, TRAILS, TREES, LAWNS AND
SITE ELEMENTS DURING PLANTING OPERATIONS. ANY DAMAGE TO SAME SHALL BE REPAIRED AT NO
COST TO THE OWNER.
CONTRACTOR SHALL VERIFY ALIGNMENT AND LOCATION OF ALL UNDERGROUND AND ABOVE GRADE
UTILITIES. CONTRACTOR TO PROVIDE THE NECESSARY PROTECTION FOR THE UTILITIES BEFORE
CONSTRUCTION / MATERIAL INSTALLATION BEGINS. CONTRACTOR TO NOTIFY GENERAL CONTRACTOR
OF ANY CONCERNS PRIOR TO INSTALLATION OF PLANTINGS.
EXISTING CONTOURS, TRAILS, VEGETATION, CURB / GUTTER AND OTHER EXISTING ELEMENTS BASED
UPON INFORMATION SUPPLIED TO LANDSCAPE ARCHITECT BY OTHERS. CONTRACTOR SHALL VERIFY
ANY AND ALL DISCREPANCIES PRIOR TO CONSTRUCTION AND NOTIFY LANDSCAPE ARCHITECT OF
SAME.
THE ALIGNMENT AND GRADES OF THE PROPOSED WALKS, TRAILS AND / OR ROADWAYS ARE SUBJECT
TO FIELD ADJUSTMENT REQUIRED TO CONFORM TO LOCALIZED TOPOGRAPHIC CONDITIONS AND TO
MINIMIZE TREE REMOVAL AND GRADING. ANY CHANGE IN ALIGNMENT MUST BE APPROVED BY
LANDSCAPE ARCHITECT.
VERIFY EXISTING / PROPOSED IRRIGATION SYSTEM LAYOUT AND CONFIRM COMPLETE LIMITS OF
IRRIGATION PRIOR TO SUPPLYING SHOP DRAWINGS.
LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN IRRIGATION LAYOUT PLAN
AND SPECIFICATION AS A PART OF THE SCOPE OF WORK WHEN BIDDING. THESE SHALL BE APPROVED
BY THE LANDSCAPE ARCHITECT PRIOR TO ORDER AND / OR INSTALLATION. IT SHALL BE THE
LANDSCAPE CONTRACTORS RESPONSIBILITY TO INSURE THAT ALL SODDED / SEEDED AND PLANTED
AREAS ARE IRRIGATED PROPERLY, INCLUDING THOSE AREAS DIRECTLY AROUND AND ABUTTING
BUILDING FOUNDATION.
THE LANDSCAPE CONTRACTOR SHALL PROVIDE THE OWNER WITH AN IRRIGATION SCHEDULE
APPROPRIATE TO THE PROJECT SITE CONDITIONS AND TO PLANT MATERIAL GROWTH REQUIREMENTS.
IRRIGATION SYSTEM IS NOT TO SPRINKLE ACROSS PAVEMENT NOR SHALL THE SYSTEM SPRINKLE THE
BUILDING.
THE SYSTEM SHALL INCORPORATE A RAIN SENSOR INTO IRRIGATION SYSTEM.
PLANTINGS OUTSIDE THE LIMITS OF IRRIGATION ARE TO BE WATERED REGULARLY UNTIL PLANTING /
SOD / SEED HAS BEEN ESTABLISHED.
GENERAL NOTES IRRIGATION NOTES
N
SCALE IN FEET
0 20 40
TOLL FREE: 1-800-252-1166
TWIN CITY AREA: 651-454-0002
Gopher State One Call
CALL BEFORE YOU DIG!
WARNING:
THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL
EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN
MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES.
THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT
LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES,
CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE
DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED
DURING CONSTRUCTION AT NO COST TO THE OWNER.
LANDSCAPING SHALL BE PROVIDED THAT MEETS THE MINIMUM LANDSCAPING BUDGET PROVIDED IN
THE TABLE IN SEC. 20-1179 LANDSCAPE BUDGET.
ESTIMATED PROJECT COST: $3,600,000
REQUIRED: $30,000 + 0.25% OF PROJECT VALUE IN EXCESS OF $3,00,000
-30,000 + (0.25% * 3,600,000) = $39,000
LANDSCAPE REQUIREMENTS
LOUCKS
W:\2026\260351\CADD DATA\LANDSCAPE\_dwg Sheet Files\L2-1 LANDSCAPE DETAILS12755 Highway 55, Suite R100
Plymouth, MN 55441
763.424.5505
www.loucksinc.com
PLANNING
CIVIL ENGINEERING
LAND SURVEYING
LANDSCAPE ARCHITECTURE
ENVIRONMENTAL
CA DD f il es pr epar ed by t he Co ns ul tan t f or th is pr oje ct ar e
instruments of the Consultant professional services for use solely
with respect to this project. These CADD files shall not be used
on other projects, for additions to this project, or for completion
o f t h i s p r o j e ct b y o t h e r s w i t h o u t w r i t t e n a pp r o va l by t h e
Con su lt ant . W it h the C onsul ta nt 's appr ova l, othe rs ma y be
p e r m i t ted to ob tain co p ies o f t h e C AD D d r a win g f i l e s f o r
inf ormation and reference only. All intentional or unintentional
revisions, additions, or deletions to these CADD f iles shall be
made at the full risk of that party making such revisions, additions
or deletions and that party shall hold harmless and indemnify the
Consultant from any & all responsibilities, claims, and liabilities.
CADD QUALIFICATION
QUALITY CONTROL
PROFESSIONAL SIGNATURE
SUBMITTAL/REVISIONS
BLAZE
CREDIT UNION
CHANHASSEN
320 Lake Drive East
Chanhassen, MN 55317
2025 Larpenteur Ave. W.
Falcoln Heights, MN 55113
C1-1 DEMOLITION PLAN
C2-1 SITE PLAN
C3-1 GRADING PLAN
C3-2 SWPPP
C3-2 SWPPP NOTES
C4-1 SANITARY AND WATERMAIN PLAN
C4-2 STORM SEWER PLAN
C8-1 CIVIL DETAILS
C8-2 CIVIL DETAILS
L0-1 TREE REPLACEMENT PLAN
L1-1 LANDSCAPE PLAN
L2-1 LANDSCAPE DETAILS
10/02/26 ENTITLEMENTS SUBMITTAL
SHEET INDEX
Douglas D. Loken - LA
Review Date
SHEET INDEX
License No.
Date
I hereby certify that this plan, specification or report was
prepared by me or under my direct supervision and that
I am a duly Licensed Landscape Architect under the laws
of the State of Minnesota.
45591
Project Lead
Drawn By
Checked By
Loucks Project No.260351
BMJ
DDL
DDL
10/02/26
-
LANDSCAPE
DETAILS
L2-1
2x ROOT BALL WIDTH
SET PLANT ON UNDISTRUBED NATIVE SOIL
SCARIFY BOTTOM AND SIDES OF HOLE PRIOR
TO PLANTING
EDGE CONDITION VARIES
WOOD STAKE
BACKFILL WITH IN SITU TOPSOIL
MULCH - 4" DEEP. NO MULCH IN CONTACT WITH
TRUNK - SEE NOTES OR SPECS.
ROOT FLARE EVEN WITH OR JUST ABOVE GRADE
SAFETY FLAGGING - ONE PER WIRE
TREE WRAP TO FIRST BRANCH
16"X2" POLYPROPYLENE OR POLYETHYLENE STRAP
NOTES:
1.THE CONTRACTOR IS RESPONSIBLE FOR
MAINTAINING ALL TREES IN A PLUMB
POSITION THROUGH THE WARRANTY
PERIOD. STAKING IS SUGGESTED, BUT NOT
REQUIRED. ANY STAKING MUST CONFORM
WITH PRACTICES AS DEFINED IN A.N.A.
GUIDELINES FOR STANDARD PRACTICES.
2.PRUNE DAMAGED AND CROSSING
BRANCHES AFTER PLANTING IS COMPLETE.
3.CUT BACK WIRE BASKET.
4.WATER TREE THOROUGHLY DURING
PLANTING OPERATIONS. PLACE BACKFILL IN
8-12" LIFTS AND SATURATE SOIL WITH
WATER. DO NOT COMPACT MORE THAN
NECESSARY TO MAINTAIN PLUMB.
5.CONTRACTOR IS RESPONSIBLE FOR
TESTING PERCOLATION RATES PRIOR TO
PLANTING. NOTIFY LANDSCAPE ARCHITECT
IMMEDIATELY IF POOR DRAINAGE EXISTS.
DETAIL - DECIDUOUS TREE
3/4" 1
-"
CUT ROPES AND EXPOSE TOP 1/3 OF BURLAP BALL.
REMOVE NON-BIODEGRADABLE MATERIAL.
PLANT-TREE-1
1
2 x ROOT BALL WIDTH
NOTES:
1.THE CONTRACTOR IS RESPONSIBLE FOR
MAINTAINING ALL TREES IN A PLUMB
POSITION THROUGH THE WARRANTY
PERIOD. STAKING IS SUGGESTED, BUT NOT
REQUIRED. ANY STAKING MUST CONFORM
WITH PRACTICES AS DEFINED IN A.N.A.
GUIDELINES FOR STANDARD PRACTICES.
2.PRUNE ANY DAMAGED BRANCHES AFTER
PLANTING IS COMPLETE.
3.WATER TREE THOROUGHLY DURING
PLANTING OPERATIONS. PLACE BACKFILL IN
8-12" LIFTS AND SATURATE SOIL WITH
WATER. DO NOT COMPACT MORE THAN
NECESSARY TO MAINTAIN PLUMB.
4.CONTRACTOR IS RESPONSIBLE FOR
TESTING PERCOLATION RATES PRIOR TO
PLANTING. NOTIFY LANDSCAPE ARCHITECT
IMMEDIATELY IF POOR DRAINAGE EXISTS.
DETAIL - CONIFEROUS TREE
3/4" 1
-"
SET PLANT ON UNDISTRUBED NATIVE SOIL
SCARIFY BOTTOM AND SIDES OF HOLE PRIOR
TO PLANTING
EDGE CONDITION VARIES
WOOD STAKE
BACKFILL WITH IN SITU TOPSOIL
MULCH - 4" DEEP. NO MULCH IN CONTACT WITH
TRUNK - SEE NOTES OR SPECS.
SAFETY FLAGGING - ONE PER WIRE
16"X2" POLYPROPYLENE OR POLYETHYLENE STRAP
CUT ROPES AND EXPOSE TOP 1/3 OF BURLAP BALL.
REMOVE NON-BIODEGRADABLE MATERIAL.
2
PLANT-TREE-2
NOTES:
LOOSEN ROOTS OF ALL CONTAINERIZED
PLANTS. SCARIFY BOTTOM AND SIDES
OF HOLE PRIOR TO PLANTINGBUILDING WALL (TYP)EDGE VARIES - REFER TO PLAN
EDGING MATERIAL - SEE NOTES OR SPEC.
LANDSCAPE FABRIC - SEE NOTES OR SPEC.
MULCH - 3" DEPTH - SEE NOTES OR SPEC.
PLANTING SOIL - SEE NOTES OR SPEC.
SHRUBS TO BE PLACED SO THAT TOP OF
CONTAINER SITS FLUSH WITH PROPOSED GRADE
DETAIL - SHRUB PLANTING
1" 1
-"
REFER TO SCHEDULE
18" MIN.
PREPARE BED A MIN. 4" DEEPER THAN ROOT BALL
PLANT-SHRB-1
3
VARIES
SEE SCHEDULE FOR SPACING
NOTE:
LOOSEN ROOTS OF PLANT
MATERIAL PRIOR TO PLANTINGBUILDING WALL (TYP)PLANTING SOIL - SEE NOTES
EDGE VARIES - REFER TO PLAN
EDGING MATERIAL - SEE NOTES
MULCH - 3" MIN. DEPTH - SEE NOTES
PLANTING - PERENNIAL
1" 1
-"PLANT-PER-1
4
GENERAL NOTES
COORDINATE THE PHASES OF CONSTRUCTION AND PLANTING
INSTALLATION WITH OTHER CONTRACTORS WORKING ON SITE.
NO PLANTING WILL BE INSTALLED UNTIL ALL GRADING AND
CONSTRUCTION HAS BEEN COMPLETED IN THE IMMEDIATE AREA.
ALL PLANTS TO BE INSTALLED AS PER PLANTING DETAILS. REMOVE ALL
FLAGGING AND LABELS FROM PLANTS.
IF THE LANDSCAPE CONTRACTOR IS CONCERNED OR PERCEIVES ANY
DEFICIENCIES IN THE PLANT SELECTIONS, SOIL CONDITIONS OR ANY OTHER
SITE CONDITION WHICH MIGHT NEGATIVELY AFFECT PLANT
ESTABLISHMENT, SURVIVAL OR GUARANTEE, THE CONTRACTOR MUST BRING
THESE DEFICIENCIES TO THE ATTENTION OF THE LANDSCAPE ARCHITECT
PRIOR TO PROCUREMENT AND / OR INSTALLATION.
PROTECT ALL EXISTING TREES ON SITE SCHEDULED TO REMAIN. IF EXISTING
TREES ARE DAMAGED IN ANY MANNER, ABOVE OR BELOW GROUND IN THE
ROOT SYSTEM, AN ASPHALTIC TREE PRUNING PAINT SHOULD BE APPLIED
IMMEDIATELY AFTER WOUNDING.
SOIL & GROUNDCOVER
ALL PLANTING AREAS RECEIVING PLANTED GROUND COVER, PERENNIALS,
ANNUALS, AND/OR VINES SHALL RECEIVE A MINIMUM OF 24" DEPTH OF
PLANTING SOIL (MNDOT 3877 - 2B OR EQUAL).
WHERE SOD / SEED ABUTS PAVED SURFACES, FINISHED GRADE OF SOD / SEED
SHALL BE HELD 1" BELOW SURFACE ELEVATION OF TRAIL, SLAB, CURB, ETC.
SOD ALL DESIGNATED AREAS DISTURBED DUE TO GRADING. SOD SHALL BE
LAID PARALLEL TO THE CONTOURS AND SHALL HAVE STAGGERED JOINTS.
ON SLOPES STEEPER THAN 3:1 OR IN DRAINAGE SWALES, THE SOD SHALL BE
STAKED TO THE GROUND.
LANDSCAPE CONTRACTOR SHALL VERIFY THAT SOIL AND COMPACTION
CONDITIONS ARE ADEQUATE TO ALLOW FOR PROPER DRAINAGE AT AND
AROUND THE BUILDING SITE.
PLANTINGS INFO
ALL PLANT MATERIAL SHALL COMPLY WITH THE LATEST EDITION OF THE
AMERICAN STANDARD FOR NURSERY STOCK, AMERICAN ASSOCIATION OF
NURSERYMEN. UNLESS NOTED OTHERWISE, ALL SHRUBS SHALL HAVE AT
LEAST 5 CANES AT THE SPECIFIED MINIMUM SHRUB HEIGHT OR WIDTH.
ORNAMENTAL TREES SHALL HAVE NO V CROTCHES AND SHALL BEGIN
BRANCHING NO LOWER THAN 3' ABOVE ROOT BALL. STREET AND
BOULEVARD TREES SHALL BEGIN BRANCHING NO LOWER THAN 5' ABOVE
FINISHED GRADE.
ANY CONIFEROUS TREE PREVIOUSLY PRUNED FOR CHRISTMAS TREE SALES
SHALL NOT BE USED. ALL CONIFEROUS TREES SHALL BE FULL FORM,
NATURAL TO THE SPECIES, WITHOUT PRUNING.
PRIOR TO PLANTING, FIELD VERIFY THAT THE ROOT COLLAR / ROOT FLAIR IS
LOCATED AT THE TOP OF THE BALLED & BURLAP TREE. IF THIS IS NOT THE
CASE, SOIL SHALL BE REMOVED DOWN TO THE ROOT COLLAR / ROOT FLAIR.
WHEN THE BALLED & BURLAP TREE IS PLANTED, THE ROOT COLLAR / ROOT
FLAIR SHALL BE EVEN OR SLIGHTLY ABOVE FINISHED GRADE.
ALL PROPOSED PLANTS SHALL BE LOCATED AND STAKED AS SHOWN ON
PLAN. ADJUSTMENTS IN LOCATION OF PROPOSED PLANT MATERIALS MAY BE
NEEDED IN FIELD. SHOULD AN ADJUSTMENT BE ADVISED, THE LANDSCAPE
ARCHITECT MUST BE NOTIFIED.
PLAN TAKES PRECEDENCE OVER PLANT SCHEDULE IF DISCREPANCIES IN
QUANTITIES EXIST. SPECIFICATIONS TAKE PRECEDENCE OVER NOTES.
NO PLANT MATERIAL SUBSTITUTIONS WILL BE ACCEPTED UNLESS APPROVAL
IS REQUESTED OF THE LANDSCAPE ARCHITECT BY THE LANDSCAPE
CONTRACTOR PRIOR TO THE SUBMISSION OF A BID AND / OR QUOTATION.
WRAPPING MATERIAL SHALL BE CORRUGATED PVC PIPING 1" GREATER IN
CALIPER THAN THE TREE BEING PROTECTED OR QUALITY, HEAVY,
WATERPROOF CREPE PAPER MANUFACTURED FOR THIS PURPOSE. WRAP ALL
DECIDUOUS TREES PLANTED IN THE FALL PRIOR TO 12-1 AND REMOVE ALL
WRAPPING AFTER 5-1.
FERTILIZER
ALL PLANT MATERIALS SHALL BE FERTILIZED UPON INSTALLATION WITH A
27-3-3 SLOW RELEASE FERTILIZER MIXED IN WITH THE PLANTING SOIL PER
THE MANUFACTURER'S INSTRUCTIONS. PLANTS MAY BE TREATED FOR
SUMMER AND FALL INSTALLATION WITH AN APPLICATION OF GRANULAR
27-3-3 AT 6 OZ PER 2.5" CALIPER PER TREE AND 3 OZ PER SHRUB WITH AN
ADDITIONAL APPLICATION OF 27-3-3 THE FOLLOWING SPRING IN THE TREE
SAUCER.
EDGING FOR PLANTING BEDS
BLACK METAL EDGER TO BE USED TO CONTAIN SHRUBS, PERENNIALS, AND
ANNUALS WHERE BED MEETS SOD / SEED UNLESS NOTED OTHERWISE.
PLANTING BED PREPARATION
ALL SHRUB BED MASSINGS TO RECEIVE 4" DEEP MULCH AND FIBER MAT
WEED BARRIER.
ALL TREES NOT IN PLANTING BEDS TO RECEIVE 4" DEEP HARDWOOD MULCH
RING WITH NO MULCH IN DIRECT CONTACT WITH TREE TRUNK.
SPREAD GRANULAR PRE EMERGENT HERBICIDE (PREEN OR EQUAL) PER
MANUFACTURER'S RECOMMENDATIONS UNDER ALL MULCHED AREAS.
MAINTENANCE STRIPS TO HAVE EDGER AND MULCH AS SPECIFIED /
INDICATED ON DRAWING OR IN SPECIFICATION.
INSPECTION AND WARRANTY
CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST FOR THE OWNER
ACCEPTANCE INSPECTION OF ALL LANDSCAPE AND SITE IMPROVEMENTS.
CONTRACTOR IS RESPONSIBLE FOR ON-GOING MAINTENANCE OF ALL
NEWLY INSTALLED MATERIALS UNTIL TIME OF OWNER ACCEPTANCE. ANY
ACTS OF VANDALISM OR DAMAGE WHICH MAY OCCUR PRIOR TO OWNER
ACCEPTANCE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
CONTRACTOR SHALL PROVIDE THE OWNER WITH A MAINTENANCE
PROGRAM INCLUDING, BUT NOT NECESSARILY LIMITED TO, PRUNING,
FERTILIZATION AND DISEASE / PEST CONTROL.
CONTRACTOR SHALL GUARANTEE NEW PLANT MATERIAL THROUGH ONE (1)
CALENDAR YEAR FROM THE DATE OF OWNER ACCEPTANCE.
WARRANTY (ONE (1) FULL GROWING SEASON) FOR LANDSCAPE MATERIALS
SHALL BEGIN ON THE DATE OF ACCEPTANCE BY THE LANDSCAPE ARCHITECT
AFTER THE COMPLETION OF PLANTING OF ALL LANDSCAPE MATERIALS. NO
PARTIAL ACCEPTANCE WILL BE CONSIDERED.
TIMING OF INSTALLATION
UNLESS NOTED OTHERWISE THE APPROPRIATE DATES FOR SPRING PLANT
MATERIAL INSTALLATION AND SEED / SOD PLACEMENT IS FROM THE TIME
GROUND HAS THAWED TO JUNE 15.
FALL SODDING IS GENERALLY ACCEPTABLE FROM AUGUST 15 - NOVEMBER 1.
FALL SEEDING FROM AUGUST 15 - SEPTEMBER 15; DORMANT SEEDING IN
THE FALL SHALL NOT OCCUR PRIOR TO NOVEMBER 1. FALL CONIFEROUS
PLANTING MAY OCCUR FROM AUGUST 15 - OCTOBER 1 AND DECIDUOUS
PLANTING FROM THE FIRST FROST UNTIL NOVEMBER 15. PLANTING OUTSIDE
THESE DATES IS NOT RECOMMENDED. ANY ADJUSTMENT MUST BE
APPROVED IN WRITING BY THE LANDSCAPE ARCHITECT.
TREES ARE NOT TO BE PRUNED, REMOVED OR TRANSPLANTED BETWEEN
APRIL 15 AND JULY 1. NOTIFY LANDSCAPE ARCHITECT IF THESE DATES ARE
UNAVOIDABLE.
LANDSCAPE INSTALLATION: