Loading...
App D3 - H3-1 IMPERVIOUS AREA SUMMARY EXHIBITNO PARKING PROPOSED CREDIT UNION 5,050 SF FFE-949.25DO NOT ENTERFFE=949.25 4 44448888888 8 88888 8 88 88888888 8 8 8N SCALE IN FEET 0 20 40 IMPERVIOUS AREA SUMMARY EXHIBIT H3-1 LOUCKS W:\2026\260351\HYDROLOGY\CAD\H3-1 IMPERVIOUS AREA SUMMARY EXHIBIT12755 Highway 55, Suite R100 Plymouth, MN 55441 763.424.5505 www.loucksinc.com PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL CA DD f il es pr epar ed by t he Co ns ul tan t f or th is pr oje ct ar e instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion o f t h i s p r o j e ct b y o t h e r s w i t h o u t w r i t t e n a pp r o va l by t h e Con su lt ant . W it h the C onsul ta nt 's appr ova l, othe rs ma y be p e r m i t ted to ob tain co p ies o f t h e C AD D d r a win g f i l e s f o r inf ormation and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD f iles shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. CADD QUALIFICATION QUALITY CONTROL PROFESSIONAL SIGNATURE SUBMITTAL/REVISIONS BLAZE CREDIT UNION CHANHASSEN 320 Lake Drive East Chanhassen, MN 55317 2025 Larpenteur Ave. W. Falcoln Heights, MN 55113 C1-1 DEMOLITION PLAN C2-1 SITE PLAN C3-1 GRADING PLAN C3-2 SWPPP C3-2 SWPPP NOTES C4-1 SANITARY AND WATERMAIN PLAN C4-2 STORM SEWER PLAN C8-1 CIVIL DETAILS C8-2 CIVIL DETAILS L0-1 TREE REPLACEMENT PLAN L1-1 LANDSCAPE PLAN L2-1 LANDSCAPE DETAILS 10/02/26 ENTITLEMENTS SUBMITTAL License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. 46607 10/02/26 Brian M. Johnson - PE Review Date Project Lead Drawn By Checked By Loucks Project No. 10/02/26 BMJ BMJ BMJ 260351 IMPERVIOUS AREA SUMMARY 40,744 SF NEW & REDEVELOPED IMPERVIOUS WATER QUALITY VOLUME 1.1" x 40,744 SF = 3,735 CF = 0.086 AC-FT *THIS EXHIBIT SHOWS ALL DISTURBED IMPERVIOUS AREA. THIS DIFFERS SOME FROM THE IMPERVIOUS AREAS SHOWN ON H1-1 AND H2-1. THOSE EXHIBITS, AND CORRESPONDING HYDROCAD MODELS, ONLY EVALUATE IMPERVIOUS FLOWING INTO AND THROUGH THE SITE. BUT THIS EXHIBIT IS INTENDED TO SHOW THE MOST ENCOMPASSING AREA FOR GREATEST WQV. ALSO, THOSE EXHIBITS SHOW IMPERVIOUS ENTERING THE SITE THAT ARE NOT DISTURBED. IMPERVIOUS AREA SUMMARY EXHIBIT H3-1