Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
5 Declaration - recorded
Document Number: A792658 Filed and/or Recorded on Oct 27, 2025 10:50 AM Office of the County Recorder/Registrar of Titles Carver County, Minnesota Kaaren Lewis, County Recorder Deputy RR/NV Document Recording Fees $ 46.00 Document Total $ 46.00 Requesting Party: Custom Home Builders Title, LLC Pages: 28 This cover page has been added to this document by Carver County Land Records and is now an official part of this recorded document DECLARATION THIS DECLARATION is made this __`'�day of �__ , 20 by LEVEL 7 DEVELOPMENT, LLC, a Minnesota limited liability company (Declarant), in favor of the Riley Purgatory Bluff Creek Watershed District, a governmental subdivision of the State of Minnesota with purposes and powers pursuant to Minnesota Statutes chapters 1 03B and 1 03D (RPBCWD). RECITALS WHEREAS, Declarant is the owner of real property within the City of Chanhassen, Carver County, Minnesota, platted and legally described as: OutlotD, THE VILLASATAVIENDA, according to the recorded plat thereof, OutlotA, AVIENDA APARTMENTS, according to the recorded plat thereof, (the Property) and no one other than Declarant and TRADITION CAPITAL BANK, has any right, title or legal interest in the Property; and RPBCWD Declaration —Avienda Rowhomes 05/15/2025 WHEREAS, the Property constitutes the entirety of the land to which RPBCWD permit # 2024-078 applies; and WHEREAS, Declarant desires to subject the Property to certain conditions and restrictions related to maintenance of facilities and site conditions required by the RPBCWD as a condition of issuance of permit no. 2024-078 for the mutual benefit of the RPBCWD and Declarant. NOW, THEREFORE, Declarant makes this declaration and hereby declares that this declaration constitutes covenants to run with the Property in perpetuity, and is binding on all persons owning or acquiring any right, title or interest in the Property and their heirs, successors, personal representatives and assigns. All features requiring maintenance as specified below and on the scaled site plan for the Property attached hereto and incorporated herein as Exhibit A will be maintained in perpetuity as follows: 1. STORMWATER FACILITIES a. Stormwater detention and re -use basin(s). Stormwater detention and re -use basin(s) must be inspected at least once a year to determine if the basin's detention and re -use characteristics are adequate and continue to perform per design. Culverts and outfall structures must be inspected at least annually and kept clear of any obstructions or sediment accumulation. Sediment accumulation must be measured by a method accurate to within one vertical foot. A detention re -use basin will be considered inadequate if sediment has decreased the wet storage volume by 50 percent of its original design volume. Based on this inspection, if the stormwater basin(s) is identified for sediment cleanout, the basin(s) will be restored to its original design contours and vegetation in disturbed areas restored within one year of the inspection date. Refer to Exhibit E for BMP maintenance checklist b. Proprietary stormwater facilities. Proprietary stormwater facilities, Jellyfish Filter, will be inspected at least annually and maintained 2 as specified or recommended by the manufacturer and/or installer as described in Exhibit B. c. Stormwater Reuse systems. The Stormwater Reuse System will be inspected, including inspection points designated on Exhibit D1 and D2, and maintained as specified or recommended by the manufacturer and/or installer. The Stormwater Reuse system will be maintained as specified or recommended by the manufacturer and the maintenance will include the items listed below; provided that if the items listed below conflict with the manufacturer's final maintenance specifications or recommendations after construction of the Stormwater Reuse system, then the specification and recommendations of the manufacturer shall prevail. Refer to Exhibit E for BMP maintenance checklist i. Inspect and clean pretreatment filters, at a minimum once annually. ii. Inspect interior treatment components, at a minimum once annually. Clean and replace treatment skid components as specified by manufacturer. iii. Flow meter: A flow meter will be operated and maintained to record water usage to help determine the ability of the Stormwater Reuse system to achieve estimated volume abstraction as set forth in the RPBCWD approved design. Records of maintenance of the flow meter and water usage shall be maintained for one year after submission of the annual report to the RPBCWD, as required in section (2) of the declaration. iv. Pervious Areas. The pervious areas designated on Exhibit C must be maintained in a pervious state for irrigation. 3 2. Written Report. Property owner will submit to the RPBCWD annually a brief written report that describes the maintenance activities performed under this Declaration, including dates, locations of inspections and the maintenance activities performed. 3. Violation. The RPBCWD may seek any remedy in law or equity against the Declarant as long as the Declarant owns the Property and thereafter against the Property Owner for a violation of this declaration. "Property Owner" as used in this declaration means the owner of the Property or a lot or outlot of record within the Property to which a maintenance obligation herein applies. 4. Recitals. The recitals set forth above are expressly incorporated herein. H IN WITNESS WHEREOF, the undersigned has executed this instrument the day and year first set forth. DECLARANT: ------------------------ Bahram Akradi, Its Manager STATE OF MINNESOTA COUNTYa, sLgtt- ) • - The foregoin=--, rument was acknowledged before me this - day of 2 y - _'L'5 _�� i ---[, as -- -- ���---- °f------^- `=�=----lic—`Z..�,��� LLB 400" STACEY M CARLSON Notary Public State of Minnesota My Commission Expires January31, 2026 This instrument was drafted by: Landform Professional Services 105 So. Fifth Avenue Suite 513 Minneapolis, MN 55401 -- --------------------- Notary Public EXHIBIT A NORTHWEST POND FILTRATION BASIN - wFT�AIVp B NORTHWEST POND LU '' / RE -USE BASIN Z ,' OUTLOT D � J m THE VILLAS AT AVIENDA ROW co AVIENDA PKW/Y w o Project boundary a UNDERGROUND DETENTION BASIN. REFER TO MAINTENANCE PLAN UNDER PERMIT 2025-029 ROW CENTRAL POND - OUTLOT A 0- DETENTION AND /' ' ' /' ' ' AVIENDA APARTMENTS UJ o RE -USE BASIN _ z o Project mBoundary JELLYFISH - ROW J4 FILTER gVVD' ROW g�UFF cvEK, BLUFF CREEK BLVD. ROW STORMWATER DETENTION & RE -USE BASIN IRRIGATION RE -USE BASIN FILTRATION BASIN t NORTH WNW Immmmmid 0 300 EXHIBIT B NTEH® o ®; ENGINEERED SOLUTIONS Jellyfish° Filter Maintenance Guide �r- Jelly'isi�= JELLYFISH° FILTER INSPECTION & MAINTENANCE GUIDE Jellyfish units are often just one of many structures in a more comprehensive stormwater drainage and treatment system. In order for maintenance of the Jellyfish filter to be successful, it is imperative that all other components be properly maintained. The maintenance and repair of upstream facilities should be carried out prior to Jellyfish maintenance activities. In addition to considering upstream facilities, it is also important to correct any problems identified in the drainage area. Drainage area concerns may include: erosion problems, heavy oil loading, and discharges of inappropriate materials. TABLE OF CONTENTS Inspection and Maintenance Overview..................................................................................3 InspectionProcedure.............................................................................................................3 Maintenance Procedure.........................................................................................................4 CartridgeAssembly & Cleaning..............................................................................................5 InspectionProcess................................................................................................................7 2 1.0 Inspection and Maintenance Overview The primary purpose of the Jellyfish® Filter is to capture and remove pollutants from stormwater runoff. As with any filtration system, these pollutants must be removed to maintain the filter's maximum treatment performance. Regular inspection and maintenance are required to insure proper functioning of the system. Maintenance frequencies and requirements are site specific and vary depending on pollutant loading. Additional maintenance activities may be required in the event of non -storm event runoff, such as base -flow or seasonal flow, an upstream chemical spill or due to excessive sediment loading from site erosion or extreme runoff events. It is a good practice to inspect the system after major storm events. Inspection activities are typically conducted from surface observations and include: • Observe if standing water is present • Observe if there is any physical damage to the deck or cartridge lids • Observe the amount of debris in the Maintenance Access Wall (MAW) or inlet bay for vault systems Maintenance activities include: • Removal of oil, floatable trash and debris • Removal of collected sediments • Rinsing and re -installing the filter cartridges • Replace filter cartridge tentacles, as needed Equipment Access Manhole Structure.""-,�°4,.., Inlet Pipe., Maintenance Access Wall Downdrain Cartridge with Lid (outside of ffi" backwash pool) Cartridge C Sediment Personnel Access Outlet Pipe Hi -Flo Cartridges with Lid (inside backwash pool) Backwash Pool Weir ibrane tion Tentacles Note: Separator Skirt not shown 2.0 Inspection Timing Inspection of the Jellyfish Filter is key in determining the maintenance requirements for, and to develop a history of, the site's pollutant loading characteristics. In general, inspections should be performed at the times indicated below; or per the approved project stormwater quality documents (if applicable), whichever is more frequent. A minimum of quarterly inspections during the first year of operation to assess the sediment and floatable pollutant accumulation, and to ensure proper functioning of the system. 2. Inspection frequency in subsequent years is based on the inspection and maintenance plan developed in the first year of operation. Minimum frequency should be once per year. 3. Inspection is recommended after each major storm event. 4. Inspection is required immediately after an upstream oil, fuel or other chemical spill. 3.0 Inspection Procedure The following procedure is recommended when performing inspections: 1. Provide traffic control measures as necessary. 2. Inspect the MAW or inlet bay for floatable pollutants such as trash, debris, and oil sheen. 3. Measure oil and sediment depth in several locations, by lowering a sediment probe until contact is made with the floor of the structure. Record sediment depth, and presences of any oil layers. 4. Inspect cartridge lids. Missing or damaged cartridge lids to be replaced. 5. Inspect the MAW (where appropriate), cartridge deck and receptacles, and backwash pool weir, for damaged or broken components. 3.1 Dry weather inspections • Inspect the cartridge deck for standing water, and/or sediment on the deck. • No standing water under normal operating conditions. • Standing water inside the backwash pool, but not outside the backwash pool indicates, that the filter cartridges need to be rinsed. Inspection Utilizing Sediment Probe 3 Standing water outside the backwash pool is not anticipated and may indicate a backwater condition caused by high water elevation in the receiving water body, or possibly a blockage in downstream infrastructure. Any appreciable sediment (>_ 1/16") accumulated on the deck surface should be removed. 3.2 Wet weather inspections • Observe the rate and movement of water in the unit. Note the depth of water above deck elevation within the MAW or inlet bay. • Less than 6 inches, flow should be exiting the cartridge lids of each of the draindown cartridges (i.e. cartridges located outside the backwash pool). • Greater than 6 inches, flow should be exiting the cartridge lids of each of the draindown cartridges and each of the hi-flo cartridges (i.e. cartridges located inside the backwash pool), and water should be overflowing the backwash pool weir. • 18 inches or greater and relatively little flow is exiting the cartridge lids and outlet pipe, this condition indicates that the filter cartridges need to be rinsed. 4.0 Maintenance Requirements Required maintenance for the Jellyfish Filter is based upon results of the most recent inspection, historical maintenance records, or the site specific water quality management plan; whichever is more frequent. In general, maintenance requires some combination of the following: 1 . Sediment removal for depths reaching 12 inches or greater, or within 3 years of the most recent sediment cleaning, whichever occurs sooner. 2. Heatable trash, debris, and oil removal. 3. Deck cleaned and free from sediment. 4. Filter cartridges rinsed and re -installed as required by the most recent inspection results, or within 12 months of the most recent filter rinsing, whichever occurs sooner. 5. Replace tentacles if rinsing does not restore adequate hydraulic capacity, remove accumulated sediment, or if damaged or missing. It is recommended that tentacles should remain in service no longer than 5 years before replacement. 6. Damaged or missing cartridge deck components must be repaired or replaced as indicated by results of the most recent inspection. 7. The unit must be cleaned out and filter cartridges inspected immediately after an upstream oil, fuel, or chemical spill. Filter cartridge tentacles should be replaced if damaged or compromised by the spill. 5.0 Maintenance Procedure The following procedures are recommended when maintaining the Jellyfish Filter: 1. Provide traffic control measures as necessary. Open all covers and hatches. Use ventilation equipment as required, according to confined space entry procedures. Caution: Dropping objects onto the cartridge deck may cause damage. 3. Perform Inspection Procedure prior to maintenance activity. 4. To access the cartridge deck for filter cartridge service, descend into the structure and step directly onto the deck. Caution: Do not step onto the maintenance access wall (MAW) or backwash pool weir, as damage may result. Note that the cartridge deck may be slippery. 5. Maximum weight of maintenance crew and equipment on the cartridge deck not to exceed 450 lbs. 5.1 Filter Cartridge Removal 1. Remove a cartridge lid. Remove cartridges from the deck using the lifting loops in the cartridge head plate. Rope or a lifting device (available from Contech) should be used. Caution: Should a snag occur, do not force the cartridge upward as damage to the tentacles may result. Wet cartridges typically weigh between 100 and 125 lbs. Replace and secure the cartridge lid on the exposed empty receptacle as a safety precaution. Contech does not recommend exposing more than one empty cartridge receptacle at a time. 5.2 Filter Cartridge Rinsing Remove all 11 tentacles from the cartridge head plate. Take care not to lose or damage the 0-ring seal as well as the plastic threaded nut and connector. 2. Position tentacles in a container (or over the MAW), with the threaded connector (open end) facing down, so rinse water is flushed through the membrane and captured in the container. Using the Jellyfish rinse tool (available from Contech) or a low-pressure garden hose sprayer, direct water spray onto the tentacle membrane, sweeping from top to bottom along the length of the tentacle. Rinse until all sediment is removed from the membrane. Caution: Do not use a high pressure sprayer or focused stream of water on the membrane. Excessive water pressure may damage the membrane. rd 4. Collected rinse water is typically removed by vacuum hose. 5. Reassemble cartridges as detailed later in this document. Reuse 0-rings and nuts, ensuring proper placement on each tentacle. 5.3 Sediment and Flotables Extraction Perform vacuum cleaning of the Jellyfish Filter only after filter cartridges have been removed from the system. Access the lower chamber for vacuum cleaning only through the maintenance access wall (MAW) opening. Be careful not to damage the flexible plastic separator skirt that is attached to the underside of the deck on manhole systems. Do not lower the vacuum wand through a cartridge receptacle, as damage to the receptacle will result. 2. Vacuum floatable trash, debris, and oil, from the MAW opening or inlet bay. Alternatively, floatable solids may be removed by a net or skimmer. Vacuuming Sump Through MAW 3. Pressure wash cartridge deck and receptacles to remove all sediment and debris. Sediment should be rinsed into the sump area. Take care not to flush rinse water into the outlet pipe. 4. Remove water from the sump area. Vacuum or pump equipment should only be introduced through the MAW or inlet bay. 5. Remove the sediment from the bottom of the unit through the MAW or inlet bay opening. For larger diameter Jellyfish Filter manholes (>_8-ft) and some vaults complete sediment removal may be facilitated by removing a cartridge lid from an empty receptacle and inserting a jetting wand (not a vacuum wand) through the receptacle. Use the sprayer to rinse loosened sediment toward the vacuum hose in the MAW opening, being careful not to damage the receptacle. 5.4 Filter Cartridge Reinstallation and Replacement 1. Cartridges should be installed after the deck has been cleaned. It is important that the receptacle surfaces be free from grit and debris. 2. Remove cartridge lid from deck and carefully lower the filter cartridge into the receptacle until head plate gasket is seated squarely in receptacle. Caution: Do not force the cartridge downward; damage may occur. 3. Replace the cartridge lid and check to see that both male threads are properly seated before rotating approximately 1/3 of a full rotation until firmly seated. Use of an approved rim gasket lubricant may facilitate installation. See next page for additional details. 4. If rinsing is ineffective in removing sediment from the tentacles, or if tentacles are damaged, provisions must be made to replace the spent or damaged tentacles with new tentacles. Contact Contech to order replacement tentacles. 5.5 Chemical Spills Caution: If a chemical spill has been captured, do not attempt maintenance. Immediately contact the local hazard response agency and contact Contech. 5.6 Material Disposal The accumulated sediment found in stormwater treatment and conveyance systems must be handled and disposed of in accordance with regulatory protocols. It is possible for sediments to contain measurable concentrations of heavy metals and organic chemicals (such as pesticides and petroleum products). Areas with the greatest potential for high pollutant loading include industrial areas and heavily traveled roads. Sediments and water must be disposed of in accordance with all applicable waste disposal regulations. When scheduling maintenance, consideration must be made for the disposal of solid and liquid wastes. This typically requires coordination with a local landfill for solid waste disposal. For liquid waste disposal a number of options are available including a municipal vacuum truck decant facility, local waste water treatment plant or on -site treatment and discharge. Jellyfish Filter Components & Filter Cartridge Assembly and Installation TAME AND COVER TOP SLAB CARTRIDGE HI-FLO CARTI OUTLET PI IGROUIED CARTRIDGE RECEPTACLE RISER SECTION 1 WITH JELLYIWI DECK MASTIC SEALAP IAT EACH 1O1N1) SEPARATORS TABLE 1: BOM ITEM NO. DESCRIPTION 1 JF HEAD PLATE 2 JF TENTACLE 3 JFO-RING 4 JF HEAD PLATE GASKET 5 JF CARTRIDGE EYELET 6 JF 141N COVER 7 JF RECEPTACLE 8 BUTTON HEAD CAP SCREW M6X14MM SS 9 JF CARTRIDGE NUT TABLE 2: APPROVED GASKET LUBRICANTS PART NO. MFR DESCRIPTION 78713 LA -CO LUBRI-JOINT 40501 HERCULES DUCK BUTTER 30600 OATEY PIPE LUBRICANT PSLUBXLIQ PROSELECT PIPE JOINT LUBRICANT 6 CARTRIDGE LID: ORIFICE DIAMETER PER PROJECT DRAWING C-RING: INSTALLED WITH WITH EACH MEMBRANE FILTRATION TENTACLE r� V I ,,1 v 1' CA RTRIDGERECEPTACLE: SECURED TO CARTRIDGE DECK 1 ENSURE EYE BOLTS ARE ALIGNED ^ TO FACILITATE LIFTING DEVICE E SEE NOTE FOR LUBRICATION DETAILS B SCREW, BUTTON HEAD CAP REQUIRES SMM HEX WRENCH NOTES: Head Plate Gasket Installation: Install Head Plate Gasket (Item 4) onto the Head Plate (Item 1) and liberally apply a lubricant from Table 2: Approved Gasket Lubricants onto the gasket where it contacts the Receptacle (Item 7) and Cartridge Lice (ITem 6). Follow Lubricant manufacturer's instructions. Lid Assembly: Rotate Cartridge Lid counter -clockwise until both male threads drop down and properly seat. Then rotate Cartridge Lid clock -wise approximately one-third of a full rotation until Cartridge Lid is firmly secured, creating a watertight seal. N. Date/Time: Inspector: Maintenance Contractor: Visible Oil Present: (Y/N) Oil Quantity Removed: Floatable Debris Present: (Y/N) Floatable Debris Removed: (Y/N) Water Depth in Backwash Pool Draindown Cartridges externally rinsed and recommissioned: (Y/N) New tentacles put on Draindown Cartridges: (Y/N) Hi -Flo Cartridges externally rinsed and recommissioned: (Y/N) New tentacles put on Hi -Flo Cartridges: (Y/N) Sediment Depth Measured: (Y/N) Sediment Depth (inches or mm): Sediment Removed: (Y/N) Cartridge Lids intact: (Y/N) Observed Damage: Comments: eft is V C :NTECH' Support ENGINEERED SOLUTIONS • Drawings and specifications are available at www.conteches.com/jellyfish. 800.338.1122 • Site -specific design support is available from Contech Engineered Solutions. www.ConteChES.Com • Find a Certified Maintenance Provider at www.conteches.com/ccmp © 2021 Contech Engineered Solutions LLC, a QUIKRETE Company Contech Engineered Solutions LLC provides site solutions for the civil engineering industry. Contech's portfolio includes bridges, drainage, sanitary sewer, stormwater, wastewater treatment and earth stabilization products. For information on other Contech segment offerings, visit ContechES.com or call 800.338.1122 NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY. APPLICATIONS SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS, AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY APPLICATION. CONTECH MAKES NO WARRANTY WHATSOEVER, EXPRESS OR IMPLIED, RELATED TO THE APPLICATIONS, MATERIALS, COATINGS, OR PRODUCTS DISCUSSED HEREIN. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH. SEE CONTECH'S CONDITIONS OF SALE (AVAILABLE AT WWWCONTECHES.CCA/COS) FOR MORE INFORMATION. Jellyfish Maintenance 01/21 EXHIBIT C N RE USE BASIN VOLUME Ir IPAI WTION CONTROLLER :UTURE PHASE CONSTRUCTION ... .. 7 FUTURE PHASE CONSTRUCTION I// / u' � OUTLOT D rfr// / • OUTLOT C / l r JSTRUCTION i • /PHASE I CONSTRU2'FION - LOT A 1' / y OCIAVIENDA LANE(PR� m � / a RASE )CONSTRUCTION t I LLS DRIVE `� I g X OUTLOT A OUTLOT B ( ( y I IRRIWiIONREUSE � I I a I IRRIG4710N /,' / )UTLOTB I // •44 OUTLOTA OUT LOTAFiAq`gTF/ / - T BLU FCREEK BLVD Q��E AVIENDA LANE S_'IIj� /T PHASE I CONSTRucTJON l JF L� I P:r,I=nln Irrigation System F 249,057 s.f. Irrigation System H 26,832 s.f. Irrigation mainline C t NORTH 0 300 Exhibit C: Irrigation Areas AVIENDA REGIONAL PLAN • Chanhassen, MN Stormwater Maintenance Agreement • 10.22.2025 EXHIBIT D w H- Lu W U O U) I w J O 2 z Q LL1 W Cl) O F— z CO a m U U of LL.I W CO O CO 0 0 Z O i =- o� •ee• a U m m m m ee z u1 + N p Z a W n o p SM LU w Q LL \ _.. \... N Q \ B9BA z.. O 6zfiA o W.. w m co g C/J � O u LZAB d w = F-w�e0 o �cm w � yam Z �6 l99B0 0 d. LV99 F i I. U) W i / a Ot Y6A lZ6A x = r 69969 z y l0'E68 fi E6A m��s CBBA 92 e w Cizt? o N o w- ems@ z U) w Q J m O w z M 2 F— U Z O O CO � � 2-1 w O O O ry Q C) CO C) w IO Q Q Z O F- U W U N U O U d v 0 Z O a z Z LU — a _. ... c0 o m LL�m - o LLC�LU co A q I $ co s e O. w U � t o, oo as.i oo�ao.t J I�s c Z ��o� I a e� z rn rn m n S a = w •ca � a � n u n o a lit w s z\ HE o %2 o u EXHIBIT E 10 Inspection Date: Property Name: City: Owner Name: Email Address: Exhibit E BMP Maintenance Inspection Checklist Stormwater Reuse Infrastructure (For Private Installations Only) Time: A.M. / P.M. Address: State (initials): Zip Code: (If applicable) Owner Change Since Last Inspected? Site Conditions: Phone Number: Y/N Rainfall in Last 24-48 Hours? Y / N *Inspection Frequency Key: A = Annually (required); S = Semi-annually (spring & autumn); Q = Quarterly, excluding winter; M = Monthly; P = Post -storm event "Maintenance Key: x = Needs immediate attention; ✓ = O.K.; N/A = Not Applicable; ? = Clarification Needed Stormwater Reuse System — To be Inspected by Irrigation Company Inspection Items Inspection Maintenance** Corrective Actions Frequency* (if necessary) Pumps, Filters, and Treatment 1. Pumps in working order A Follow manufacturer's (use manufacturer's recommendations recommendations) 2. Follow the pump A - fall Follow manufacturer's manufacturer's recommendations recommendations for winterization 3. Filters clean A Clean filters 4. Control system operating A Repair/replace control system per design Page 112 5. No blockages in sprinkler A Remove blockages or replace pipes pipe 6. Sprinklers heads are all A Fix/replace sprinkler heads operational 7. Stormwater tank/cistern free A Remove sediment of excessive sediment 8. Other A Additional Comments: Inspector Name (Print): Inspector Signature: Estimated Date of Next Inspection: Page 212 Inspection Date: Property Name: City: Owner Name: Exhibit E BMP Maintenance Inspection Checklist (For Private Installations Only) Time: _ Address: State (initials) Email Address: (If applicable) Owner Change Since Last Inspected? Site Conditions: Phone Number: Zip Code: Y/N A.M. / P.M. Rainfall in Last 24-48 Hours? Y / N *Inspection Frequency Key: A = Annually (required); S = Semi-annually (spring & autumn); Q = Quarterly, excluding winter; M = Monthly; P = Post -storm event **Maintenance Key: X = Needs immediate attention; ✓ = O.K.; N/A = Not Applicable; ? = Clarification Needed Storm Sewer — Pipe & Structures Inspection Items Inspection Frequency* Maintenance** Corrective Actions (if necessary) Catch Basins, Manholes, Pipes, & Flared End Sections 1. Inlets clear A Clear inlets of debris 2. Castings in good condition A Replaced damaged castings 3. No sediment in bottom of structure A Remove sediment 4. No trash in bottom of structure or in grates A Remove trash or debris 5. Concrete or masonry condition is good A Patch poor areas a. No cracks or displacements A Seal cracks Page 112 b. No spalling —minor: <1- in.; major: rebar exposed A Patch major spalled areas c. No joint failures A Seal joints d. Dog houses good A Patch dog houses e. Water tightness good A Patch leaks 6. Other (specify) A Manufactured Treatment Devices (use Manhole section above also) 1. All sections of the Jellyfish Filter Inspection and Maintenance Log are complete A Follow manufacturer's recommendations Additional Comments: Inspector Name (Print): Inspector Signature: Estimated Date of Next Inspection: Page 212 CONSENT AND SUBORDINATION TRADITION CAPITAL BANK, a Minnesota banking corporation, the holder of a Combination Mortgage, Assignment of Lease and Rents, Security Agreement and Fixture Financing Statement on all or part of the Property more particularly described in the foregoing Stormwater Maintenance Agreement, which Mortgage is dated July 1, 2021 and recorded July 2, 2021 as Document No. A728034 with the offices of the Carver County Recorder, Minnesota, and which Mortgage was amended by Amendment to Combination Mortgage, Assignment of Lease and Rents, Security Agreement and Fixture Financing Statement dated December 27, 2022 and recorded December 28, 2022 as Document No. A755936 with the offices of the Carver County Recorder, Minnesota, hereby consents to the recording of the attached declaration and agrees that its rights in the property affected by the declaration will be subordinated thereto. IN WITNESS WHEREOF, TRADITION CAPITAL BANK, a Minnesota corporation, has caused this consent and subordination to be executed this _day of C e_--_, 2025. TRADITION CAPTIAL BANK a Minnesota Corp n BY =`mil ---------- Patrick Kasid Its Senior Vice President STATE OF MINNESOTA)11 ) r, , ) ss. COUNTY OF ) T e foregoing instrument was acknowledged before me this rtfday of --------- 2025, by Patrick Kasid, as Senior Vice President of Tradition Capital Bank, a Minnesota banking corporation, on behalf of said entity. MEAGAN JEAN REINKE;�_r E NOTARY PUBLIC f' MINNESOTA Notary PO is My Commission Expires 01/31/2031 RPBCWD Consent & Subordination — Avienda Rowhomes